Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
12 JUN 2012 - 16 AUG 2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.6315 (Flammability)
GLP compliance:
no
Type of method:
closed cup
Key result
Flash point:
182.2 °C
Atm. press.:
1 013 mBar

Atmospheric pressure: 1005 mbar

Flash point at the ramp mode 182ºC

Flash point at the automatic mode:

Determination 1: 182ºC

Determination 2: 182ºC

Mean Flash point: 182 ± 0ºC

Flash point after adjustment to an atmospheric pressure of 1013 mbar: 182.2 ± 0.0ºC

Interpretation of results:
GHS criteria not met
Remarks:
EU GHS criteria not met
Conclusions:
The flashpoint at 1013 mbar is 182.2 ± 0.0 ºC.
Executive summary:

The flash point test was done according to EU Method A.9. Closed cop method was used. The flashpoint at 1013 mbar is 182.2 ± 0.0 ºC.

Description of key information

The flash point test was done according to EU Method A.9. Closed cop method was used. The flashpoint at 1013 mbar is 182.2 ± 0.0 ºC.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
182.2 °C

Additional information