Registration Dossier

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
July 12th to 27th 2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Tests performed according to guideline.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report Date:
2010

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
no

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
Product Name: L-Carnitine-L-Tartrate
Producer: Chengda Pharmaceuticals Co., Ltd., China
Batch No.: 1001003
Manufacturing Date: 2010.01.03
Expiry Date: 2012.01.02

Results and discussion

Flammable solids
Test procedure:
burning time (test type not further specified)
Remarks:
or specified in description of method (migrated information)
Burning time:
960 s
Remarks on result:
other: not highly flammable

Applicant's summary and conclusion

Conclusions:
Not highly flammable
Executive summary:

Preliminary screening have proven the burning time is 960s. Therefore the substance can be considered as nit highly flammable.