Registration Dossier

Toxicological information

Eye irritation

Currently viewing:

Administrative data

Endpoint:
eye irritation: in vivo
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: see 'Remark'
Remarks:
The study has been performed according to OECD and EC guidelines and according to GLP principles. The data relating to the identity, purity and stability of the test material are not mentioned in the test report but can be retrieved from the original NONS notification.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1999
Report Date:
1999

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
other: Annex V
Qualifier:
according to
Guideline:
OECD Guideline 405 (Acute Eye Irritation / Corrosion)
Deviations:
no
Qualifier:
according to
Guideline:
EU Method B.5 (Acute Toxicity: Eye Irritation / Corrosion)
Deviations:
no
GLP compliance:
yes

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
Nature of substance: Undiluted liquid
- Name of test material (as cited in study report): CETEC 2254
- Label: IS-97-1688
- Physical state: straw coloured liquid
- Analytical purity: not indicated

Test animals / tissue source

Species:
other: Rabbit (New Zealand White)

Test system

Vehicle:
unchanged (no vehicle)
Amount / concentration applied:
.1 ML
Number of animals or in vitro replicates:
3

Results and discussion

In vivo

Resultsopen allclose all
Irritation parameter:
conjunctivae score
Remarks:
(redness)
Basis:
animal #1
Remarks:
(mean score 1)
Time point:
other: overall at 24, 48 and 72 h
Score:
0
Irritation parameter:
conjunctivae score
Remarks:
(redness)
Basis:
animal #2
Remarks:
(mean score 2)
Time point:
other: overall at 24, 48 and 72 h
Score:
0.3
Irritation parameter:
conjunctivae score
Remarks:
(redness)
Basis:
animal #3
Remarks:
(mean score 3)
Time point:
other: overall at 24, 48 and 72 h
Score:
0.3
Irritation parameter:
conjunctivae score
Remarks:
(redness)
Max. score:
1
Remarks on result:
other: Max. duration: 24 h; Max. value at end of observation period: 0 (related to all animals)
Irritation parameter:
chemosis score
Basis:
animal #1
Remarks:
(mean score 1)
Time point:
other: overall at 24, 48 and 72 h
Score:
0
Irritation parameter:
chemosis score
Basis:
animal #2
Remarks:
(mean score 2)
Time point:
other: overall at 24, 48 and 72 h
Score:
0
Irritation parameter:
chemosis score
Basis:
animal #3
Remarks:
(mean score 3)
Time point:
other: overall at 24, 48 and 72 h
Score:
0
Irritation parameter:
chemosis score
Max. score:
0
Remarks on result:
other: Max. duration: h; Max. value at end of observation period: 0 (related to all animals)
Irritation parameter:
cornea opacity score
Basis:
animal #1
Remarks:
(mean score 1)
Time point:
other: overall at 24, 48 and 72 h
Score:
0
Irritation parameter:
cornea opacity score
Basis:
animal #2
Remarks:
(mean score 2)
Time point:
other: overall at 24, 48 and 72 h
Score:
0
Irritation parameter:
cornea opacity score
Basis:
animal #3
Remarks:
(mean score 3)
Time point:
other: overall at 24, 48 and 72 h
Score:
0
Irritation parameter:
cornea opacity score
Max. score:
0
Remarks on result:
other: Max. duration: h; Max. value at end of observation period: 0 (related to all animals)
Irritation parameter:
iris score
Basis:
animal #1
Remarks:
(mean score 1)
Time point:
other: overall at 24, 48 and 72 h
Score:
0
Irritation parameter:
iris score
Basis:
animal #2
Remarks:
(mean score 2)
Time point:
other: overall at 24, 48 and 72 h
Score:
0
Irritation parameter:
iris score
Basis:
animal #3
Remarks:
(mean score 3)
Time point:
other: overall at 24, 48 and 72 h
Score:
0
Irritation parameter:
iris score
Max. score:
0
Remarks on result:
other: Max. duration: h; Max. value at end of observation period: 0 (related to all animals)
Irritant / corrosive response data:
Reversibility of any observed effect: Changes fully reversible within 2 days
Other effects:
No corneal or iridial effects were noted. Moderate
conjunctival irritation was noted in all treated eyes at 1
hour, minimal conjunctival irritation in two eyes at 24
hours. Treated eyes appeared normal 48 after treatment.

Applicant's summary and conclusion

Interpretation of results:
other: not classified