The physico-chemical properties of the members of the category, including HXL-833, are summarized in the table below. The data show, that all substances have similar physico-chemical propererties. Therefore, the category approach is justified.

See also Report 491517_Read-across approach for REACH registration of HXL-8366, attached under 1. General information

 

 

EC #

Avg MW

Melting Point [°C]

Boiling Point [°C]

Relative density at 20oC

Vapour Pressure [Pa] at 20oC

Vapour Pressure [Pa] at 20oC (calc.)

Water Solubility [µg/L]

Partition Coefficient (log Kow)

Flash point [°C]

Flammability

Pyrophoric properties

Explosive properties

Auto-ignition temperature [°C]

451-070-8

525

< -80.5

dec >350

0.99

7.5 E-03

-

<200*

>6.7*

120.5

no

no

no

395

451-120-9

537

< -80.5

dec >360

0.99

4.5 E-03

-

<200*

>6.7*

1294

no

no

no

415

451-190-0

544

 -541

399

0.90

4.13

6.2 E-03

<110*

>7.0*

2662

no

no

no

395

453-150-8

554

-571

385

0.99

1.23

1.2 E-02

<200*

>6.7*

2572

no

no

no

395

451-200-3

585

 -511

399

0.98

6.23

6.2 E-03

<100*

>7.0*

2542

no

no

no

405

430-320-1

611

< -20

dec >177

0.96

2.7 E-08

-

<65*

>6.2

229

no

no

no

396

451-110-4

613

 -71

396

0.97

4.93

7.1 E-03

<100*

>7.0*

2602

no

no

no

395

451-400-0

637

< -80.5

dec >175

0.97

5.7 E-03

-

<200*

>6.7*

215.5

no

no

no

405

451-220-2

648

 -361

399

0.96

1.93

6.2 E-03

<100*

>7.0*

2602

no

no

no

400

451-180-6

652

 -211

393

0.96

2.43

8.2 E-03

<100*

>7.0*

2932

no

no

no

405

452-180-9

657

 -301

386

0.97

0.383

1.1 E-02

<200*

>6.7*

2742

no

no

no

415

453-470-8

783

< -80

dec >180

1.03

6.4 E-03

-

<100*

>7.0*

215

no

no

no

405

452-270-8

883

 -451

383

1.01

1.83

1.3 E-02

<100*

>7.0*

232

no

no

no

Read-across

453-480-2

1012

 -71

378

0.98

0.223

1.7 E-02

<140*

>6.9*

251.5

no

no

no

Read-across

444-000-2

1023

-201

dec >170

0.98

< 1E-03

-

<77.5**

>6.2 at 40°C

223

no

no

no

> 400

453-450-9

1036

 -231

380

0.98

0.133

1.5 E-02

<16

>7.8*

217.5

no

no

no

Read-across

453-490-7

1066

 -291

383

0.97

0.173

1.3 E-02

<9*

>8.0*

245.5

no

no

no

Read-across

453-460-3

1094

-10 to -80

dec >180

0.96

0.162

-

<100*

>7.0*

238

no

no

no

Read-across

700-325-4

878

< -80

dec >350

1.00

< 1.33 E-08

-

<1.89**

>6.5*

244

no

no

no

400

 

* = value based on limit of quantification, i.e. limit of water solubility

** = value based on limit of detection

1value for pour point

2open cup method

3Measured values are higher than expected. This was probably caused by the small amount of water present in the samples. Therefore, where possible, vapour pressures were calculated based on their measured boiling temperature using the Modified Watson Correlation method described by Lyman (Lyman, Reehl, Rosenblatt (eds.), "Handbook of chemical property estimation methods", McGraw-Hill Book Company, 1990).

4result of preliminary test, main test was 196ºC

Avg MW = Average molecular weight