Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
19 July 2011
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Certificate of Analysis
Qualifier:
according to guideline
Guideline:
ISO No., other: Petroleum products-Determination of flash and fire point - Cleveland open cup method
Qualifier:
according to guideline
Guideline:
ISO No., other: Standard Test Method for Flash und Fire Points by Cleveland Open Cup - ASTM D92-97
Qualifier:
according to guideline
Guideline:
ISO No., other: Determination of open flash and fire point - Cleveland method -IP 36/84 (1989)
GLP compliance:
no
Type of method:
open cup
Flash point:
159 °C
Atm. press.:
1 013 hPa

Description of key information

159 °C at 1013 hPa (Cleveland Open Cup method)

Key value for chemical safety assessment

Flash point at 101 325 Pa:
159 °C

Additional information