Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
explosive properties of explosives
Type of information:
experimental study
Adequacy of study:
key study
Study period:
from 1992-20-02 to 1992-10-02
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
Version / remarks:
publication no. L251, September 1984
Deviations:
no
GLP compliance:
yes
Parameter:
other: More sensitive to heating than m-dinitrobenzene
Remarks on result:
negative (not further specified)
Parameter:
other: More sensitive to friction than m-dinitrobenzene
Remarks on result:
negative (not further specified)
Parameter:
other: Explosive under influence of flame
Remarks on result:
negative (not further specified)
Key result
Test series:
UN Test series 1
Method:
UN Test 1 (b): Koenen test
Parameter:
limiting diameter (mm)
Value:
6
Result:
negative, no propagation of detonation
Key result
Test series:
UN Test series 3
Method:
UN Test 3 (b) (i): BAM friction apparatus
Parameter:
limiting load (N)
Value:
360
Result:
negative, no explosion
Key result
Test series:
UN Test series 3
Method:
UN Test 3 (a) (ii): BAM Fallhammer
Parameter:
other: height (cm)
Value:
100
Result:
negative, not sensitive to detonative shock

1. Thermal sensitivity:

- Method : Koenen test

- Results: jet diameter (mm) / start of reaction (s) / result

2 / 67* / no splints, barrell unchanged

2 / 68* / no splints, barrell unchanged

2 / 70* / no splints, barrell unchanged

6 / 60* / no splints, barrell unchanged

6 / 62* / no splints, barrell unchanged

6 / 60* / no splints, barrell unchanged

* total reaction time: 120 -125 s.

The test item is not explosive under the influence of heating (embedding).

2. Mechanical sensitivity:

- 1. Method: drop hammer

- Results: mass (kg) / height (cm) / total test / no reaction / partial decomposition / explosion

10 / 40 / 6 / 6 / 0 / 0

10 / 100 / 6 / 6 / 0 / 0

Results: 6 times negative. The test item was not sensitive to impact.

- 2. Method: BAM apparatus (friction)

- Parameters:

stress: 360 N

- Results: 6 times negative. The test item is not sensitive to friction.

Overall summary:

The test item is not explosive according to EC Regulation 84/449 EWG Test A14.

Interpretation of results:
GHS criteria not met
Conclusions:
The test item was assessed for its explosive properties regarding sensitivity to heat, shock and friction. The results showed that the test item was not explosive.
Executive summary:

The test item was assessed for its explosive properties regarding sensitivity to heat, shock and friction in accordance to EU method A.14. The results showed that the test item was not explosive.

Description of key information

In a study the test item was assessed for its explosive properties regarding sensitivity to heat, shock and friction. Thus, the results showed that the test item was not explosive.

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

The test item was assessed for its explosive properties regarding sensitivity to heat, shock and friction in accordance to EU method A.14. The results showed that the test item was not explosive.

Justification for classification or non-classification

Based on the results of the study assessing explosive properties and sensitivity to heat, shock and friction, the test item has not to be classified with respect to explosiveness.


Further, based on the structure of the molecule and taking into account the provisions laid down in Regulation (EC) No 1272/2008 (CLP), as amended for the twelfth time in Regulation (EU) 2019/521, the test item does not have to be classified with respect to explosiveness.