Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Description of key information

Key value for chemical safety assessment

Skin sensitisation

Link to relevant study records
Reference
Endpoint:
skin sensitisation: in vitro
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is classified as skin corrosion (Category 1, 1A, 1B or 1C)
Endpoint conclusion
Endpoint conclusion:
no study available
Additional information:

In accordance with column 2 of REACH Annex VIII, testing for skin sensitisation is not necessary as the substance is classified as corrosive to the skin according to the EU Classification, Labelling and Packaging of Substances and Mixtures (CLP) Regulation (EC) No. 1272/2008 (H314, Category 1B).

Respiratory sensitisation

Endpoint conclusion
Endpoint conclusion:
no study available

Justification for classification or non-classification

In accordance with column 2 of REACH Annex VIII, no testing for skin sensitisation was performed as the substance is classified as corrosive to the skin according to the CLP (regulation (EC) 1272/2008). Therefore, no data are available which justify a classification.