Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Experimental part in November 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Version / remarks:
April 2004
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.8 (Partition Coefficient - HPLC Method)
Version / remarks:
May 2008
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
HPLC method
Partition coefficient type:
octanol-water
Specific details on test material used for the study:
Designation in Test Facility: 16082904G
Date of Receipt: 29. Aug. 2016
Condition at Receipt: Room Temperature, in proper conditions
Name: ROC-601
Batch no.: S23PSG0816
Appearance: White crystalline powder
Composition: 99.5% purity, see analytical certificate
CAS No.: 439661-46-8
EINECS-No.: Not yet assigned
Molecular formula: C20H26O5
Molecular weight: 346.42 g/mol
Purity: 99.5% by LC-UV
Homogeneity: Uniform crystalline powder
Stability: H2O: unknown; EtOH: unknown; acetone: unknown; CH3CN: unknown; DMSO: unknown
Solubility: H2O: unknown; EtOH: unknown; acetone: unknown; CH3CN: unknown; DMSO: unknown
Production date: 29. Jun. 2016
Expiry date: Jul. 2017
Storage: Room temperature (20 ±5 °C), keep away from light
Analytical method:
high-performance liquid chromatography
Type:
log Pow
Partition coefficient:
5.182
Temp.:
25 °C
pH:
7.59
Remarks on result:
other: average of triplicate measurements
Details on results:
Measurement Data
The retention times of the test item are presented as follows:
Measurement 1 RT: 14.856 min.
Measurement 2 RT: 14.896 min.
Measurement 3 RT: 14.949 min.
Mean RT: 14.900 min.
Standard deviation: 0.047

Calculated Values
The calculated values for Capacity Factor, log Capacity Factor, log POW Test Item are presented as follows:
Measurement 1: K = 9.7120; log k = 0.9873; log POW = 5.178
Measurement 2; K = 9.7414; log k = 0.9886; log POW = 5.181
Measurement 3; K = 9.7797; log k = 0.9903; log POW = 5.186
Mean: log POW = 5.182
Standard deviation is 0.004

log POW was calculated from the capacity factor as follows: log POW = (log k + 0.8606) / 0.3569

Using the correlation log k / log POW, the log POW of the major components of test item ROC-601 was calculated as 5.182 ±0.004 (mean ±standard deviation).
Validity
The validity criteria and results are presented as follows:
Range (Max – Min. log POW) <0.1; found: 0.008 and therefore valid
Value within Range of Ref. Items 1.70 - 6.20; found 5.182 and therefore valid

Reference ItemsMeasurement Data

The retention times which were recorded for the reference items are presented in the following table.

Compound

RT 1

RT 2

RT 3

RT 4

RT 5

RT 6

 

min.

min.

min.

min.

min.

min.

Thiourea

1.387

1.387

1.387

1.387

1.387

1.387

Acetophenone

2.139

2.140

2.144

2.144

2.143

2.142

Naphthalene

5.051

5.055

5.074

5.078

5.076

5.079

Diphenyl ether

6.642

6.648

6.672

6.683

6.679

6.683

Phenanthrene

9.272

9.275

9.301

9.333

9.327

9.336

Fluoranthene

12.660

12.664

12.690

12.758

12.752

12.764

Triphenylamine

21.956

21.854

21.866

22.055

22.030

22.075

DDT

30.047

29.917

29.861

30.168

30.167

30.262

 

Calculated Values: For each reference item, the calculated capacity factors are presented in the following table.

Compound


Retention Time

Mean

Retention Time
Standard
Deviation

Retention Time
Relative
Standard Deviation

k

 

min.

min.

%

 

Thiourea

1.387

0.000

0.022

0

Acetophenone

2.142

0.002

0.089

0.5446

Naphthalene

5.069

0.013

0.248

2.6551

Diphenyl ether

6.668

0.018

0.276

3.8081

Phenanthrene

9.307

0.029

0.312

5.7112

Fluoranthene

12.715

0.049

0.385

8.1683

Triphenylamine

21.972

0.096

0.437

14.8439

DDT

30.070

0.157

0.522

20.6830

 

log POW/ log k: The values for log k and log POW of the reference items are presented in the following table:

Compound

log k

log POW

Acetophenone

-0.2639

1.70

Naphthalene

0.4241

3.60

Diphenyl ether

0.5807

4.20

Phenanthrene

0.7567

4.50

Fluoranthene

0.9121

4.70

Triphenylamine

1.1715

5.70

DDT

1.3156

6.20

 

Graph Correlation Results

Dead time is 1.387 ± 0.000 minutes, with RSD 0.02%.

The RSD of the retention times of the reference items were all below 0.6 %.

Equation of the regression: log k = 0.3569 * log POW – 0.8606 with a coefficient of determination r2= 0.9916

Conclusions:
The log POW of the test item ROC-601 was calculated as 5.182 ±0.004 (mean ±standard deviation)
Executive summary:

The study was performed using a HPLC with a C18 column. Seven reference items with different retention times and thiourea for the determination of the dead time were used to produce a calibration curve, since retention time on hydrophobic columns and POW are correlated. The reference items were chosen based on the results of the pre-test.

One vial was filled with the reference item mix and one vial with the test item solution. The vials were analysed using the HPLC. First one injection from the solvent blank methanol/water 75/25 (v/v) was made. Then three injections were measured from the reference item mix, three injections from the test item and again three injections from the reference item mix.

For each reference item, the capacity factor k was calculated from the retention time of thiourea and the retention time of the respective reference item.

A calibration function (log k versus log POW, linear fit) was determined using the literature values for POW of the reference items and the retention times in the six determinations.

 

The test item showed one Peak with a retention time of 14.900 min with a low standard deviation of 0.047 min. Using the correlation log k / log POW, the log POW of the test item ROC-601 was calculated as 5.182 ±0.004 (mean ±standard deviation).

Description of key information

A study according to OECD method 117 was performed using a HPLC column. Seven reference items, chosen based on the results of the pre-test, with different retention times and thiourea for the determination of the dead time were used to produce a calibration curve, since retention time on hydrophobic columns and POWare correlated.

One vial was filled with the reference item mix and one vial with the test item solution. The vials were analysed using the HPLC. First one injection from the solvent blank methanol/water 75/25 (v/v) was made. Then three injections were measured from the reference item mix, three injections from the test item and again three injections from the reference item mix.

For each reference item, the capacity factor k was calculated from the retention time of thiourea and the retention time of the respective reference item.

A calibration function (log k versus log POW, linear fit) was determined using the literature values for POW of the reference items and the retention times in the six determinations.

The test item showed one Peak with a retention time of 14.900 min with a low standard deviation of 0.047 min.

Using the correlation log k / log POW, the log POW of the test item ROC-601 was calculated as 5.182 ±0.004 (mean ±standard deviation).

Key value for chemical safety assessment

Log Kow (Log Pow):
5.182
at the temperature of:
25 °C

Additional information