Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016-08-02 to 2016-09-01
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7950 (Vapor Pressure)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
effusion method: isothermal thermogravimetry
Key result
Test no.:
#1
Temp.:
20 °C
Vapour pressure:
>= 0 - < 0 hPa
Key result
Test no.:
#2
Temp.:
25 °C
Vapour pressure:
>= 0 - < 0 hPa

The calculated vapour pressure of the substance (Table 4) was outside of the validated range of the method. Therefore vapour pressure of the substance is reported as less than the vapour pressure of bezo(ghi)perylene i.e. the reference substance with the lowest vapour pressure used during validation of the method.

Conclusions:
The vapour pressure of the substance at 20°C (293K) is < 1.3E-8 Pa and at 25°C (298K) is < 1.9E-8 Pa.
Executive summary:

The calculated vapour pressure of the substance was outside of the validated range of the method. Therefore vapour pressure of the substance is reported as less than the vapour pressure of bezo(ghi)perylene i.e. the reference substance with the lowest vapour pressure used during validation of the method.

Description of key information

The calculated vapour pressure of the substance was outside of the validated range of the method. Therefore vapour pressure of the substance is reported as less than the vapour pressure of bezo(ghi)perylene i.e. the reference substance with the lowest vapour pressure used during validation of the method.

Key value for chemical safety assessment

Vapour pressure:
0 hPa
at the temperature of:
20 °C

Additional information