Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

General advice : Never give anything by mouth to an unconscious person.
Inhalation : If inhaled, remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Call a poison control center or doctor for treatment advice.

Skin contact : Take off all contaminated clothing immediately. Rinse skin immediately with plenty of water for 15-20 minutes. Wash contaminated clothing before re-use.

Eye contact : Hold eye open and rinse slowly and gently with water for 15-20 minutes. Remove contact lenses, if present, after the first 5 minutes, then continue rinsing eye. Call a poison control center or doctor for treatment advice.

Ingestion : Have person sip a glass of water if able to swallow. DO NOT induce vomiting unless directed to do so by a physician or poison control center. Never give anything by mouth to an unconscious person. Call a poison control center or doctor for treatment advice.

Most important symptoms/effects, acute and delayed : No applicable data available.

Protection of first-aiders : No applicable data available.

Notes to physician : No applicable data available.

Fire-fighting measures

Suitable extinguishing media : Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Unsuitable extinguishing media : No applicable data available.

Specific hazards : No applicable data available.

Special protective equipment for firefighters : Wear full protective clothing and self-contained breathing apparatus.

Further information : Evacuate personnel and keep upwind of fire. If area is heavily exposed to fire and if conditions permit, let fire burn itself out since water may increase the area contaminated. Do not allow run-off from fire fighting to enter drains or water courses. Cool containers/tanks with water spray. Fire residues and contaminated fire extinguishing water must be disposed of in accordance with local regulations.

Accidental release measures

Safeguards (Personnel) : Evacuate personnel, thoroughly ventilate area, use self-contained breathing apparatus. Use personal protective equipment.

Environmental precautions : No applicable data available.

Spill Cleanup : Clean-up methods - small spillage Sweep up or vacuum up spillage and collect in suitable container for disposal. Avoid generating dust. Clean-up methods - large spillage Prevent further leakage or spillage. Use approved industrial vacuum cleaner for removal. Shovel into suitable container for disposal.

Accidental Release Measures : Dispose of in accordance with local regulations.

Handling and storage

Handling (Personnel) : Avoid contact with skin, eyes and clothing. Wash hands thoroughly with soap and water after handling and before eating, drinking, chewing gum, using tobacco, or using the toilet. Avoid breathing dust or vapour.

Handling (Physical Aspects) : No applicable data available.

Dust explosion class : No applicable data available.

Storage : Keep container tightly closed in a dry and well-ventilated place. Do not store or consume food, drink or tobacco in areas where they may become contaminated with this material.

Storage period : No applicable data available.

Storage temperature : No applicable data available.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Engineering controls : Use only with adequate ventilation. Personal protective equipment

Respiratory protection : Where there is potential for airborne exposures in excess of applicable limits, wear approved respiratory protection with dust/mist cartridge.

Hand protection : Material: Protective gloves

Eye protection : Wear safety glasses with side shields. Additionally wear a face shield where the possibility exists for face contact due to splashing, spraying orairborne contact with this material.

Skin and body protection : Where there is potential for skin contact have available and wear as appropriate impervious gloves, apron, pants, and jacket.
Exposure Guidelines

Exposure Limit Values: : No applicable data available

Stability and reactivity

Reactivity : No applicable data available.

Chemical stability : No applicable data available.

Possibility of hazardous reactions : The hazardous reactivity of this material is unknown. Do not mix with other materials unless specifically instructed to do so under the guidance of a trained chemist.

Conditions to avoid : Avoid contact with: Heat, flames and sparks. Elevated temperature

Incompatible materials : No applicable data available.

Hazardous decomposition products : No applicable data available

Disposal considerations

Waste disposal methods – Product : Treatment, storage, transportation, and disposal must be in accordance with applicable federal, state/provincial, and local regulations.

Contaminated packaging : No applicable data available.