Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

Emergency measure - Inhalation: General emergency measures for keeping the respiratory tract

open.

Emergency measure - Eyes: Immediately flush opened eyes with plenty of water. Get

medical attention.

Emergency measure - Skin: Immediately wash off with plenty of water and soap. Remove

contaminated clothing.

Emergency measure - Ingestion: Induce drinking of water. Induce vomiting. Get medical

attention.

Fire-fighting measures

Recommended extinguishing agent: Powder, foam, spray water or water mist. Fire extinguisher:

carbon dioxide, powder, water.

Product arising from burning: Carbon dioxide, carbon monoxide, nitrogen oxides.

Product determined by test: N

Protective equipment: Suitable chemical protective clothing and self-contained

breathing apparatus.

Accidental release measures

Emergency measures in case of spillage: 1. Evacuate all persons from dangerous area. In case of

higher amount of the substance warn also persons in

vicinity.

2. Ensure appropriate ventilation.

3. Remove or switch off all sources of ignition.

4. Soak substance with water and keep it wet.

5. Normaly this type of substance should be allowed to

burn without trying to extinguish it.

6. Use non sparkling tools to gather spill material and

seall in bags.

7. This substance may burn slowly, if ignited with no

confinement.

8. It may explode, if ignited with confienment.

9. Rinse spill site with water.

10. Dispose the substance in sealed bags to incineration.

Handling and storage

Handling: Measures for safe handling and personal protective equip-

ment:

All work processes must always be designed so that exposure

to the substance by inhalation and skin/eye contact is as

low as possible. Skin and eye contact with the substance is

to be avoided. If technical exhaust or ventilation measures

are not possible or not sufficient, respiratory protection

must be worn:filtering half-mask FFP/P2.

To protect against direct skin contact tested gloves (basic

material: Nitrile; 0.1 mm; 480 min.; 60 min) must be worn.

Safe eye protection is required: Goggles with lateral

protection.

Normal working clothes are required.

Information related to protection against fire and

explosion:

Protect against the effect of heat. Avoid smoking, open

fire, spark formation.

Work hygiene:

Emergency showers must be installed.

Sufficient washing facilities must be available.

Eye douches must be provided and their location must be

marked conspicuously. Do not eat, drink or smoke in the

working area.Change contaminated clothing immediately.

Outdoor clothes must be kept separate from working clothes.

Storage: Keep container tightly closed, in a cool (at room tempera-

ture) and well ventilated area.

Packaging of the substance and or preparation: Special drums made of cardboard.The used vessels are proofed

in accordance to the regulation of the transportation of

dangerous goods.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport: The product should be transported only in well closed
containers. The containers must be protected against fall.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: No reaction with water.

Chemical reaction with water: No reaction with water.

Dust explosion: Not relevant.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: Recovery by mechanical collection.

Industry - Possibility of neutralisation: Neutralisation by water treatment.

Industry - Possibility of destruction: controlled discharge: Only incineration suitable.

Industry - Possibility of destruction - incineration: Incinerate in other specific incinerators (rotating

incinerator for explosives).

Industry - Possibility of destruction - water purification: Removal, not specified.

Public at large - Possibility of recovery/recycling: Recovery by mechanical collection.

Public at large - Possibility of neutralisation: Neutralisation by water treatment.

Public at large - Possibility of destruction: controlled discharge: Only incineration suitable.

Public at large - Possibility of destruction - incineration: Incinerate in other specific incinerators (rotating

incinerator for explosives).

Public at large - Possibility of destruction - water purification: Removal, not specified.