Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Version / remarks:
EC Regulation No.440/2008 - Annex A.10.
Deviations:
not specified
GLP compliance:
yes
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
other: the sample was ignited within 2 min; after removal of ignition, the sample didn’t propagate combustion either by burning with flame or smouldering along 200 mm of the train within the 4 min.

Preliminary test: Phenomena and results from two independent preliminary screening tests, were identical as following:

- the sample was ignited within 2 min;

- after removal of ignition, the sample didn’t propagate combustion either by burning with flame or smouldering along 200 mm of the train within the 4 min.

Main test: Omitted due to the result of the preliminary test.

It can be ascertained that the sample is not a highly flammable solid based on the results of

the preliminary screening test.

Interpretation of results:
GHS criteria not met
Conclusions:
The sample is not a highly flammable solid based on the results of the preliminary screening test.
Executive summary:

In this guideline ( EC Regulation No.440/2008 - Annex A.10) study conducted with GLP certification, the test material (EC 254-935-6) was determined not to meet the criteria for classification as a flammable solid under the EU Classificaiton, Labelling and Packaging (CLP) regulation (1272/2008). The test material ignited briefly, but rapidly extinguished and failed to propagate.

Description of key information

Flammable solids study carried out according to guideline and with GLP compliance.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification

Based upon the key studies, the substance was determined not to meet the criteria for classification as a flammable solid under the EU Classification, Labelling, and Packaging (CLP) regulation (1272/2008).