Endpoint:
vapour pressure
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the melting point is above 300°C
Justification for type of information:
In common with other inorganic salts, there is not considered to be a measurable vapour pressure
Cross-reference
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Justification for type of information:
Using recognised methods described incompany report. This also corrolates with published data suggesting no melting point < 300 C
Qualifier:
equivalent or similar to guideline
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
Principles of method if other than guideline:
Melting point estimate was carried out using a Maplelab Scientific Melting Point Device MPD02 up to 300 C
A further sample was heated in a carbolite furnace to 900 C (after which it has changed to a dark ash, therefore decomposition had occurred)
GLP compliance:
no
Type of method:
capillary method
Specific details on test material used for the study:
Batch number of test material: A-09-03021
Key result
Melting / freezing pt.:
> 300 °C
Atm. press.:
ca. 1 atm
Decomposition:
yes
Remarks:
Above 300 C and below 900 C
Decomp. temp.:
> 300 - < 900 °C
Sublimation:
no

Substance does not melt .The substance decomposes > 300 C.

The MPD02 equipment could only go up to 300 C and at this temperature no physical or colouration changes were observed in the crystalline sample placed in the glass capillary tube.

A 1 g sample was heated in a carbolite furnace to 900 C after which it has changed to a dark ash, therefore decomposition had occurred.

Conclusions:
Results: Substance does not melt .The substance decomposes >300 °C.

During normal use and handling, and certainly under biological and environmental conditions, the substance will remain solid.

Data source

Materials and methods

Results and discussion