Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
1995
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Valid method
Principles of method if other than guideline:
Grewer test according to company guideline and hot storage test
Relative self-ignition temperature:
>= 240 °C
Remarks on result:
other:
Remarks:
at atm. press. of ca.1013.0 hPa

The sample shows self-ignition in the Grewer oven starting at 240 °C.

The hot storage test at 140 °C reveals warming of the sample to max. 141 °C.

time to temperature equalisation: 8 h 14 min

time from temp. equalisation to max. temp.: 59 min

total time to max. temp.: 9 h 13 min

Conclusions:
The test substance shows self-ignition at 240 °C in the Grewer screening test. Hot storage test at 140 °C in the 1 L wire basket results in a max. sample temp. of 141 °C.
Executive summary:

Self-heating of the test substance was determined by a screening test in the Grewer oven and by a hot storage test. The test substance shows self-ignition at 240 °C in the Grewer screeningtest. The hot storage test at 140 °C in the 1 L wire basket results in a max. sample temp. of 141 °C. The test substance is not self-heating at 140 °C.

Description of key information

Self-ignition temperature >= 240°C

Key value for chemical safety assessment

Additional information