Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
24 July - 29 Aug 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
Although the substance is a solid, a melting point of 32.7 °C necessitates flash point testing as a liquid.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
other: Eraflash-point tester

Test material

Constituent 1
Chemical structure
Reference substance name:
2,2'-[(1,1-dimethylethyl)imino]bisethanol
EC Number:
218-480-7
EC Name:
2,2'-[(1,1-dimethylethyl)imino]bisethanol
Cas Number:
2160-93-2
Molecular formula:
C8H19NO2
IUPAC Name:
2-[tert-butyl(2-hydroxyethyl)amino]ethan-1-ol
Test material form:
liquid

Results and discussion

Flash point
Key result
Flash point:
142 °C
Atm. press.:
1 013 hPa

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The closed cup method was applied for the determination of the flash-point of t-Butyldiethanolamine.
The flash-point of the test item was 142°C.
Executive summary:

Information

Guideline(s)

Result

Comment

Flash-point

EC A.9
UN paragr. 32.4.1
ASTM D 93
ISO 2719

142°C

 

closed cup method