Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2015-07-20
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Remarks:
In compliance with a relevant quality system (ISO 9001:2008)
Qualifier:
according to guideline
Guideline:
DIN 51562 Part 1 (Viscometry - Measurement of kinematic viscosity by means of the Ubbelohde viscometer - Part 1: Viscometer specification and measurement procedure)
Deviations:
no
GLP compliance:
no
Other quality assurance:
other: ISO 9001 (2008)
Type of method:
capillary viscometer (static)
Remarks:
Ubbelohde
Key result
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
0.772

Test: 1

Capillary tube: Oc

Correction factor: 0.003144

Measured time [s]

Mean value [s]

247

246

246

246

243

246

 

Calculation

Viscosity [mm2/s]

time (mean value) x correction factor = viscosity

0.7734

 

Test: 2

Capillary tube: Oa

Correction factor: 0.004936

Measured time [s]

Mean value [s]

156

156

156

156

156

156

 

Calculation

Viscosity [mm2/s]

time (mean value) x correction factor = viscosity

0.7700

 

Viscosity at 20 °C [mm2/s]

0.772

Conclusions:
A kinematic viscosity value of 0.772 mm2/s at 20°C was determined for the substance in accordance with a relevant test method and in compliance with a known quality system (ISO 9001:2008). The result is considered to be reliable.

Description of key information

Viscosity: 0.772 mm2/s at 20°C (DIN 51562)

Key value for chemical safety assessment

Viscosity:
0.772 mm²/s (static)
at the temperature of:
20 °C

Additional information

A kinematic viscosity value of 0.772 mm2/s at 20°C was determined for the substance using a relevant test method and in compliance with a known quality system (ISO 9001:2008). The result is considered to be reliable and is selected as key study.

 

The key study is supported by a dynamic viscosity value of 0.6 mPa s at 20°C which was reported in a handbook (Budavari 1989) which has been subject to peer-review and in which the original data sources are traceable.

 

In available secondary sources to which reliability could not be assigned, dynamic viscosity values in the range of 0.65 - 1.8 mPa s at 20-25°C were reported for the substance.