Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 217-303-0 | CAS number: 1806-29-7
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Administrative data
First-aid measures
Description of first aid measures
Eye Contact Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.
Skin Contact Wash off immediately with soap and plenty of water while removing all contaminated clothes and shoes. In the case of skin irritation or allergic reactions see a physician.
Ingestion Clean mouth with water. Get medical attention.
Inhalation Remove from exposure, lie down. Move to fresh air. If symptoms persist, call a physician. If breathing is difficult, give oxygen. If not breathing, give artificial respiration.
Self-Protection of the First Aider Ensure that medical personnel are aware of the material(s) involved, take precautions to protect themselves and prevent spread of contamination.
Most important symptoms and effects, both acute and delayed
Causes eye burns.
Indication of any immediate medical attention and special treatment needed
Notes to Physician Treat symptomatically.
Fire-fighting measures
Extinguishing media
Suitable Extinguishing Media
Water spray. Carbon dioxide (CO 2). Dry chemical. alcohol-resistant foam.
Extinguishing media which must not be used for safety reasons
No information available.
Special hazards arising from the substance or mixture
Thermal decomposition can lead to release of irritating gases and vapors.
Hazardous Combustion Products
Carbon monoxide (CO), Carbon dioxide (CO2).
Advice for firefighters
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear. Thermal decomposition can lead to release of irritating gases and vapors.
Accidental release measures
Personal precautions, protective equipment and emergency procedures
Ensure adequate ventilation.
Environmental precautions
See Section 12 for additional ecological information.
Methods and material for containment and cleaning up
Sweep up or vacuum up spillage and collect in suitable container for disposal.
Handling and storage
Precautions for safe handling
Avoid contact with skin and eyes. Avoid contact with clothing. Avoid breathing vapors or mists. Do not ingest.
Hygiene Measures
Handle in accordance with good industrial hygiene and safety practice. Keep away from food, drink and animal feeding stuffs. Do not eat, drink or smoke when using this product. Remove and wash contaminated clothing before re-use. Wash hands before breaks and at the end of workday.
Conditions for safe storage, including any incompatibilities
Keep in a dry, cool and well-ventilated place. Keep container tightly closed.
Specific end use(s)
Use in laboratories
Transport information
Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all
Exposure controls / personal protection
Control parameters
Exposure limits
This product, as supplied, does not contain any hazardous materials with occupational exposure limits established by the region specific regulatory bodies
Biological limit values
This product, as supplied, does not contain any hazardous materials with biological limits established by the region specific regulatory bodies
Monitoring methods
BS EN 14042:2003 Title Identifier: Workplace atmospheres. Guide for the application and use of procedures for the assessment of exposure to chemical and biological agents.
Derived No Effect Level (DNEL) No information available
Predicted No Effect Concentration (PNEC) No information available
Exposure controls
Engineering Measures
Ensure adequate ventilation, especially in confined areas. Ensure that eyewash stations and safety showers are close to the workstation location.
Wherever possible, engineering control measures such as the isolation or enclosure of the process, the introduction of process or
equipment changes to minimise release or contact, and the use of properly designed ventilation systems, should be adopted to
control hazardous materials at source
Personal protective equipment
Eye Protection Goggles (European standard - EN 166)
Hand Protection Protective gloves
Disposable gloves (See manufacturers recommendations) - EN 374 (minimum requirement)
Skin and body protection Long sleeved clothing
Inspect gloves before use. observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. (Refer to manufacturer/supplier for information) gloves are suitable for the task: Chemical compatability, Dexterity, Operational conditions, User susceptibility, e.g. sensitisation effects, also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion. gloves with care avoiding skin contamination.
Respiratory Protection Follow the OSHA respirator regulations found in 29 CFR 1910.134 or European Standard EN 149. Use a NIOSH/MSHA or European Standard EN 149 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced.
To protect the wearer, respiratory protective equipment must be the correct fit and be used
and maintained properly
Large scale/emergency use In case of insufficient ventilation wear suitable respiratory equipment
Small scale/Laboratory use Use a NIOSH/MSHA or European Standard EN 149:2001 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced.
When RPE is used a face piece Fit Test should be conducted
Environmental exposure controls No information available.
Stability and reactivity
Reactivity
None known, based on information available
Chemical stability
Stable under normal conditions.
Possibility of hazardous reactions
Hazardous Polymerization Hazardous polymerization does not occur.
Hazardous Reactions No information available.
Conditions to avoid
Incompatible products.
Incompatible materials
Strong oxidizing agents.
Hazardous decomposition products
Carbon monoxide (CO). Carbon dioxide (CO2).
Disposal considerations
Waste treatment methods
Waste from Residues / Unused Products
Chemical waste generators must determine whether a discarded chemical is classified as a
hazardous waste. Consult local, regional, and national hazardous waste regulations to
ensure complete and accurate classification.
Contaminated Packaging Empty remaining contents. Dispose of in accordance with local regulations. Do not re-use empty containers.
European Waste Catalogue (EWC) According to the European Waste Catalogue, Waste Codes are not product specific, but application specific.
Other Information Waste codes should be assigned by the user based on the application for which the product was used.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.