Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
02/05/2007 - 29/05/2007
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: No data on GLP compliance, guideline study, available as unpublished report, no restrictions fully adequate for assessment
Qualifier:
according to guideline
Guideline:
ISO 13736:1997 (Petroleum products and other liquids - Determination of flash point - Abel closed cup method)
Version / remarks:
1997
Deviations:
no
GLP compliance:
not specified
Type of method:
closed cup
Flash point:
< -30 °C
Atm. press.:
1 013 hPa
Conclusions:
The flash point of 68476-55-1 is <-30°C.
Executive summary:

This study was conducted to a standard guideline and is considered fully reliable for use as a key study. The flash point of 68476-55-1 is <-30°C.

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
26/09/2007 - 04/10/2007
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: non GLP, guideline study, available as unpublished report, no restrictions fully adequate for assessment
Qualifier:
according to guideline
Guideline:
ISO 13736:1997 (Petroleum products and other liquids - Determination of flash point - Abel closed cup method)
Version / remarks:
1997
Deviations:
no
GLP compliance:
not specified
Type of method:
closed cup
Flash point:
-24 °C
Atm. press.:
1 013 hPa
Conclusions:
The flash point of 92128-65-9 is -24°C.
Executive summary:

This study was conducted to a standard guideline and is considered fully reliable for use as a key study. The flash point of 92128-65-9 is -24°C.

Description of key information

The flash point of streams in this category is from =-24.0°C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
-27 °C

Additional information

Data are available from BASF (2007 & 2007) for two streams in this category (92128-65-9: -24°C, 68476-55-1: <-30°C, all values measured at a pressure of 1013 hPa). The data will be read across to other members of the category.

The data indicate that this category would be classified as Flammability Category 1 liquid (flash point <23°C, boiling point =35°C) or Flammability Category 2 liquid (flash point <23°C, boiling point >35°C) depending on the boiling point. The flash point is <23°C and the boiling point is in the range 24°C to 101.9°C.

The mean of the flash point values value for the category is -27°C at a pressure of 1013 hPa and this has been used to complete the 'key value for chemical safety assessment'.