Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 700-652-2 | CAS number: 1259300-69-0
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Administrative data
First-aid measures
If inhaled: Remove to fresh air and keep at rest in a comfortable position for breathing. If symptoms persist, call a physician.
If on skin: Take off immediately all contaminated clothing and wash it before reuse. Wash with plenty of soap and water, If skin irritation or rash occurs: Get medical advice/attention.
If in eyes: Immediately flush with plenty of water for at least 15 minutes. Remove contact lenses if present and easy to do so. Continue rinsing.
If swallowed: Get medical advice/attention
General advice: Consult a physician if experiencing symptoms after exposure to this product. Show this safety data sheet to the doctor in attendance. Move out of a dangerous area
Fire-fighting measures
EXTINGUISHING MEDIA
Suitable extinguishing media: Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
Unsuitable extinguishing media: Water may be ineffective.
Specific hazards arising from the chemical: No Data Available
Special Protective Equipment and Precautions for Fire-Fighters: Follow standard practice
Accidental release measures
PERSONAL PRECAUTIONS, PROTECTIVE EQUIPMENTR AND EMERGENCY PROCEDURES
Advice for non-emergency personnel
Emergency procedures: Prevent further leakage or spillage if safe to do so. Keep away from Incompatible products
Advice for emergency personnel: Follow standard response procedures
ENVIRONMENTAL PRECAUTIONS
Follow all regulations regarding releases into the environment.
Follow all regulations regarding releases into sanitary sewer systems.
If the product contaminates rivers and lakes or drains, inform respective authorities.
METHODS AND MATERIALS FOR CONTAINMENT AND CLEANING UP
Contain any spills with appropriate spill media.
Use spill media to prevent spill from entering drains, sewers, or surface waters.
Keep in properly labeled containers.
Keep in suitable, closed containers for disposal.
Handling and storage
PRECAUTIONS FOR SAFE HANDLING
Use in closed system or with proper ventilation.
Use only equipment and materials which are compatible with the product.
Do not store for long periods at elevated temperatures.
Preferably transfer by pump or gravity.
CONDITIONS FOR STORAGE, INCLUDING INCOMPATIBILITIES
Storage conditions: Follow best practices for industrial chemical storage. Store in original container. Keep away from Incompatible products. For optimal product quality: Store in closed containers in a cool, dry place and blanket opened containers with dry nitrogen for extended storage.
Packaging material
Suitable material: Lined steel, Stainless steel, HD Polyethylene
Unsuitable material: Natural rubber, latex, viton
Transport information
Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all
Exposure controls / personal protection
EXPOSURE CONTROLS
Appropriate engineering controls: Ensure adequate good ventilation.of the work station.
Individual Protection Measures
Handle in accordance with good industrial hygiene and safety practice
Hand protection: Impervious gloves. Suitable material: Butyl rubber, Nitrile, SilverShield/4H. Unsuitable material: Leather, natural rubber, latex, viton.
Eye protection: Chemical resistant goggles must be worn.
Hygiene measures: Eye wash bottles or eye wash stations as described in ANSI / ISEA Z358.1-2014
Environmental exposure controls: Dispose of rinse water in accordance with local and national regulations.
Stability and reactivity
REACTIVITY: none known
CHEMICAL STABILITY: stable under recommended storage conditions.
POSSIBILITY OF HAZARDOUS REACTIONS: No Data Available
CONDITIONS TO AVOID: Excessive heat, light, contact with incompatible materials. Contact with incompatible materials: oxidizers.
INCOMPATIBLE METERIALS: Strong oxidizers.
HAZARDOUS DECOMPOSITION PRODUCTS: Hazardous decomposition products formed under fire conditions – Carbon oxides
Other decomposition products – No Data Available
Disposal considerations
Waste treatment methods: Dispose of by incineration or according to local and national regulations.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.