Registration Dossier

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1999
Report Date:
1999

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Flammable solids
Test procedure:
burning time (test type not further specified)
Remarks:
or specified in description of method (migrated information)
Burning time:
ca. 180 s
Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.

Any other information on results incl. tables

Extremely flammable (Meth A9/A2): N
Highly flammable: N
Pyrophoric substance (A13): N
Highly flammable solid (A10): N
Highly flammable liquid (A9): N
Highly flammable gas (A11): N
In contact with water substance liberates highly flammable gases (A12): N
Flammable (A9): N

Applicant's summary and conclusion

Conclusions:
TN-105 burnt with a yellow/orange flame with grey smoke. The flame went out after burning 80 mm in 3 min producing a large volume of grey smoke. The pile continued to smoulder until it had progressed 180 mm in 20 min and 25 sec.
TN-105 is not highly flammable.