Registration Dossier

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Endpoint:
flammability
Remarks:
Pyrophoric liquids/solids (migrated from section 'Flammability')
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study was performed according to OECD and EC guidelines and according to GLP principles.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1998
Report Date:
1998

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
other: Method A10 (Flammability (solids)) of Commission Directive 92/69/EEC
Deviations:
not specified
GLP compliance:
yes (incl. certificate)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
- Lot/batch No.: 6090

Results and discussion

Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record. | Remarks: | Additional remarks: The pile ignited with a blue flame, which self-extinguished after 185 seconds, without propagating combustion.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record. | Remarks: | Additional remarks: The pile ignited with a blue flame, which self-extinguished after 185 seconds, without propagating combustion.

Applicant's summary and conclusion

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
During a preliminary screening test, the pile ignited with a blue flame, which self-extinguished after 185 seconds, without propagating combustion. The result of the test obviated the need to perform the main test. The test substance is considered non flammable.