Endpoint:
oxidising liquids
Type of information:
other: statement
Adequacy of study:
key study
Study period:
July 29 - August 26, 2008
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The EU method was followed. Based on the molecular structure a statement rather than a full study was considered sufficient to cover this endpoint.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008
Report date:
2008

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.21 (Oxidising Properties (Liquids))
Deviations:
not applicable
Principles of method if other than guideline:
Not applicable
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Details on test material:
- Name of test material (as cited in study report): Nikkol VC-IP
- Substance type: Colourless liquid (determined at NOTOX)
- Physical state: Liquid
- Stability under test conditions: stable
- Storage condition of test material: At room temperature in the dark

Study design

Contact with:
other: no data

Results and discussion

Any other information on results incl. tables

Examination of the structure of the test substance establishes beyond reasonable doubt that the substance is incapable of showing a positive result in the test described in the EC A.21 guideline. The substance does not contain any group that might act as an oxidizing agent. The oxygen atoms that are present in the chemical are bonded to carbon, which indicates that the molecule is oxygen-deficient. The impurities, present for max. 5% in the test substance, were not taken into account but it is not to be expected that these make the test substance an oxidizing substance.It is also not to be expected that an interaction between the different components occurs.

Applicant's summary and conclusion

Interpretation of results:
other: no oxidising properties
Remarks:
Migrated information
Conclusions:
In conclusion, Nikkol VC-IP has no oxidizing properties.