First-aid measures

Emergency measure - Inhalation: Symptomatic treatment.
Emergency measure - Eyes: Rinse immediately with plenty of water. Seek medical
advice.
Emergency measure - Skin: Wash immediately with plenty of soap and water.
Emergency measure - Ingestion: Symptomatic treatment.

Fire-fighting measures

Recommended extinguishing agent: Recommended extinguishing agents: Water, foam, dry powder,
water mist.

Product arising from burning: Products arising from pyrolysis: Products of combustion may
contain carbon oxides, hydrogen chloride and hydrogen
fluoride, and soot.

Protective equipment: Protective equipment: Wear protective clothing and a
self-contained breathing apparatus.

Accidental release measures

Handling and storage

Handling: The usual precautions for the handling of chemicals should
be observed. Avoid ingestion and contact with skin and
eyes. Keep away from sources of ignition.

Storage: Store in tightly closed containers in a cool, dry place,
away from strong acids, alkalis and oxidising agents.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (IMDG)

Remarksopen allclose all

Air transport ICAO/IATA

Remarks
Transport: No special precautions. The product will be shipped in
polyethylene- lined steel drums.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: Other dangers: Keep away from strong oxidising agents,
strong bases and strong acids.

Chemical reaction with water: Chemical reaction with water: None reported.

Disposal considerations

Industry - Possibility of recovery/recycling: The substance can be recovered by distillation.

Industry - Possibility of neutralisation: None known.

Industry - Possibility of destruction: controlled discharge: Discharge the substance after evidence of a decrease in
fluorine and in COD content.

Industry - Possibility of destruction - incineration: The substance can be disposed of at a suitable facility.
Waste gas treatment to remove hydrogen chloride and
hydrogen fluoride gases should be fitted.

Industry - Possibility of destruction - water purification: Not recommened.