First-aid measures

Emergency measure - Inhalation: Symptomatic treatment.

Emergency measure - Eyes: Rinse immediately with plenty of water. Seek medical

advice.

Emergency measure - Skin: Wash immediately with plenty of soap and water.

Emergency measure - Ingestion: Symptomatic treatment.

Fire-fighting measures

Recommended extinguishing agent: Recommended extinguishing agents: Water, foam, dry powder,

water mist.

Product arising from burning: Products arising from pyrolysis: Products of combustion may

contain carbon oxides, hydrogen chloride and hydrogen

fluoride, and soot.

Protective equipment: Protective equipment: Wear protective clothing and a

self-contained breathing apparatus.

Accidental release measures

Handling and storage

Handling: The usual precautions for the handling of chemicals should

be observed. Avoid ingestion and contact with skin and

eyes. Keep away from sources of ignition.

Storage: Store in tightly closed containers in a cool, dry place,

away from strong acids, alkalis and oxidising agents.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport: No special precautions. The product will be shipped in
polyethylene- lined steel drums.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: Other dangers: Keep away from strong oxidising agents,

strong bases and strong acids.

Chemical reaction with water: Chemical reaction with water: None reported.

Disposal considerations

Industry - Possibility of recovery/recycling: The substance can be recovered by distillation.

Industry - Possibility of neutralisation: None known.

Industry - Possibility of destruction: controlled discharge: Discharge the substance after evidence of a decrease in

fluorine and in COD content.

Industry - Possibility of destruction - incineration: The substance can be disposed of at a suitable facility.

Waste gas treatment to remove hydrogen chloride and

hydrogen fluoride gases should be fitted.

Industry - Possibility of destruction - water purification: Not recommened.

Public at large - Possibility of recovery/recycling: The substance will not enter the public domain.