Registration Dossier

Physical & Chemical properties

Boiling point

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

The study was performed in accordance with the official with the Official Journal of the European Communities, 92/69/EEC, No L 383, method A.2, December 1992 and with the OECD guideline for the testimg of chemicals, number 103, July 1995, using the Siwoloboff method with photocell detection.
The boiling point could not be determined because CA 2342, purity 99.9 %, decomposes before the boiling point is reached. 

Key value for chemical safety assessment

Additional information

Guideline Test Type

Species

boiling point (K)

Reference

Reliability

EU A.2 (photocell detection)

Not applicable

Could not be determined because of decomposition

Das, R.; Ciba-Geigy Ltd., 1997