Registration Dossier

Administrative data

First-aid measures

Emergency measure - Inhalation: Remove patient to fresh air. Symptomatic treatment.
Emergency measure - Eyes: Rinse immediately with plenty of water for at least 15
minutes. Seek medical advice.
Emergency measure - Skin: Wash thoroughly with soap and water.
Emergency measure - Ingestion: Seek immediate medical attention.

Fire-fighting measures

Recommended extinguishing agent: Water, foam, carbon dioxide or dry powder may be used.

Product arising from burning: Products of combustion may contain oxides of carbon and
nitrogen together with hydrogen chloride and hydrogen
fluoride gas.

Product determined by test: N

Protective equipment: Full protective clothing and a self-contained breathing
apparatus should be worn.

Accidental release measures

Emergency measures in case of spillage: Wear suitable protective clothing (see 2.3.1). Ventilate the
area. Collect spill using an industrial vacuum cleaner
taking care to avoid dust formation. Transfer to suitable
containers and dispose of by incineration in accordance with
local regulations. Do not allow spill to enter public drains
or watercourses.

Handling and storage

Handling: Avoid inhalation, ingestion, skin and eye contact.
Protective overalls (PVC or Saranex-coated), gloves
(chemical resistant PVC or nitrile), goggles or faceshield
(conforming to BS 2092), boots (PVC or rubber wellingtons)
and respiratory protection (filtering facepiece respirator
conforming to EN149 type FFP25) should be worn. Wash
thoroughly after handling.

Storage: Store in a well ventilated, cool, dry place in tightly
closed containers.

Packaging of the substance and or preparation: Not given, 6th amendment notification.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (IMDG)

Remarksopen allclose all

Air transport ICAO/IATA

Remarks
Transport: No special precautions.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None reported.

Chemical reaction with water: None reported.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: Uncontaminated material may be recovered for reuse. (A611)

Industry - Possibility of neutralisation: Not applicable.

Industry - Possibility of destruction: controlled discharge: Not recommended.

Industry - Possibility of destruction - incineration: Recommended method at a suitable facility using temperatures
of 1100 deg C for 3 seconds. Waste gas treatment to remove
oxides of nitrogen and hydrogen fluoride and chloride gas
should be fitted. (A661)

Industry - Possibility of destruction - water purification: Not recommended.

Public at large - Possibility of recovery/recycling: The substance will not enter the public domain.