Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 427-430-5 | CAS number: 54301-26-7
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Toxicity to microorganisms
Administrative data
Link to relevant study record(s)
- Endpoint:
- activated sludge respiration inhibition testing
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: OECD guideline, GLP study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Remarks:
- 1996-20-02
- Analytical monitoring:
- no
- Details on test solutions:
- a stock solution (500 mg of the test substance per litre) was prepared 52 minutes before the start of the exposure, dissolving the test substance into dilution water; pH of this stock solution was adjusted to make the test substance soluble in our experimental conditions at the request of the study monitor.
The test substance concentrations in the test media were obtained adding the appropriate volumes of the stock solution in the respective test flasks.
-for each flask, a mixture of dilution water, synthetic sewage (16mL) and inoculum (200mL), was added at 12-minutes intervals, to the substance (expected for the control flasks, without any substance), to form a final volume of 500 mL per flask.
-pH was adjusted in the test media around pH 7.5-8.0 to make the test substance soluble in our experimental condtions at the request of the study monitor. - Test organisms (species):
- activated sludge
- Details on inoculum:
- mixture of different strains of micro-organisms (inoculum) found in activated sludge from a sewage treatment plant treating predominantly domestic sewage (La Fouillous - Loire - FRANCE
The sludge was used on the day of collection
the sludge was mixed during 1 minute in order to destroy the coarse particles
the concentration of suspended solids was evaluated from a small amount of sludge
the sludge was centrifugated and the suspended solids obtained were washed before to be resuspended for the preparation of the inoculum (centrifugated 3 times with deminineralized water containing synthetic sewage for 5 minutes at 2000 rpm, with discarding of the supernatants)
the suspended solids were then re-suspended into synthetic sewage so as to obtain a nominal concentration of suspended solids of approximately 2 grammes per ltre in the inoculum
this inoculum was kept aerated and at thermoregulated temperature (20 +/- 2°C) until its using for the preparation of the media - Test type:
- static
- Water media type:
- freshwater
- Total exposure duration:
- 3 h
- Test temperature:
- 19.1-23.4°C
- pH:
- from 7.49 to 7.97
- Nominal and measured concentrations:
- 1 / 10 / 100 mg/L
- Reference substance (positive control):
- yes
- Remarks:
- 3,5-dichlorophenol
- Duration:
- 3 h
- Dose descriptor:
- EC50
- Effect conc.:
- > 100 mg/L
- Nominal / measured:
- nominal
- Conc. based on:
- test mat.
- Basis for effect:
- growth inhibition
- Results with reference substance (positive control):
- ihnibition percentage after 3 hours:
26% at 5 mg/L
74% at 15 mg/L
77% at 30 mg/L - Validity criteria fulfilled:
- yes
- Conclusions:
- EC50-3 hours > 100mg/L
- Executive summary:
Inhibition of respiration in activated sludge, in compliance with OECD guideline n°209 and EEc directive 87/302
Method
-micro-organisms from activated sludge (800 mg of suspended solids per litre of medium) were exposed to a range of concentrations of test substance for 3 hours; 1, 10 , 100mg test substance per litre of test medium
-two contro media (without test substance) were tested, one at the beginning of the test, the other one at the end of the test
-the dissolved oxygen concentration was measured in 300 mL samples from each after approximately 3 hours exposure
-a reference substance, 3,5 -dichlorophenol, was tested under the same conditions in order to control the sensitivity of the activated sludge (3 concentrations)
-the criteria of quality for the study, as notified in the OECD and EEC standards and relative to the level of oxygen consumption in the two control media and to the toxicity of 3,5 -dichlorophenol, were respected
Results
Taking into account the results obtained under the experimental conditions employed, these ones may be expressed as follows:
EC50 -3 hours higher than 100 mg/L
Reference
Description of key information
Inhibition of respiration in activated sludge, in compliance with OECD guideline n°209 and EEc directive 87/302 test was performed and the (EC50 -3 hours) was found to be higher than 100 mg/L
Key value for chemical safety assessment
- EC50 for microorganisms:
- 100 mg/L
Additional information
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.