Registration Dossier

Administrative data

First-aid measures

Emergency measure - Inhalation: Remove victim to fresh air. If not breathing, give
artificial respiration. Seek medical assistance.
Emergency measure - Eyes: In case of contact with eyes, wash with copious amounts of
water. Seek medical assistance.
Emergency measure - Skin: In case of skin contact wash, with copious amounts of water.
In the even to discomfort or inflamation, seek medical
advice.
Emergency measure - Ingestion: Wash out mouth, drink water and seek immediate medical
assistance.

Fire-fighting measures

Recommended extinguishing agent: Carbon Dioxide, Water or dry chemical extinguishing media
are recommended.

Product arising from burning: The substance may burn if involved in a fire, evolving
noxious fumes (such as oxides of carbon and methacrylate
fumes).

Product determined by test: N

Protective equipment: Full protective clothing and self-contained breathing
apparatus should be worn.

Accidental release measures

Emergency measures in case of spillage: No special measures required.

Handling and storage

Handling: The substance should be stored, handled and used in

conditions of good industrial hygiene and in conformity with

any local regulations in order to avoid exposure.


Engineering controls are necessary to reduce exposure to the

substance.


When exposure cannot be prevented or adequately controlled

appropriate personal protective equipment should be worn.

Such protective equipment should conform to the appropriate

international or national standards as follows;

Chemical protective gloves to Standard EN374

Chemical resistant clothing to Standard EN368

Eye protection to Standard EN166.


When necessary appropriate respiratory protection should be

used. e.g. a dust mask conforming to EN149 FFP1.



The standards mentioned above should be regarded as a

minimum.

Storage: The substance is stored in large fibre drums. Keep
containers upright and tightly closed in a cool locations.
Keep away from sunlight and water.

Packaging of the substance and or preparation: The substance is contained in fibre drums.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (IMDG)

Remarksopen allclose all

Air transport ICAO/IATA

Remarks
Transport code: None
Transport: No special transport recommendations are required.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None known.

Chemical reaction with water: None that is hazaradous.

Dust explosion: There is a possible dust explosivity hazard from this

organic powder.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: Recovery from minor spillages or accidental discharge is not
economically or technically feasible, and such material
will be disposed of to the sewer system.

Industry - Possibility of neutralisation: Not applicable.

Industry - Possibility of destruction: controlled discharge: No special techniques required.

Industry - Possibility of destruction - incineration: The substance can be disposed of by incineration by burning
under controlled conditions at a licensed waste treatment
processor in accordance with local regulations. Stack gases
should be scrubbed, because noxious fumes (eg oxides of
carbon and methacrylate fumes) could be formed.

Industry - Possibility of destruction - water purification: The substance is normally disposed of to drains. However, no
adverse effects on sewage systems would be anticipated.

Industry - Possibility of destruction - other: Not applicable.

Public at large - Possibility of recovery/recycling: Not applicable.

Public at large - Possibility of neutralisation: Not applicable.

Public at large - Possibility of destruction: controlled discharge: Not applicable.

Public at large - Possibility of destruction - incineration: Not applicable.

Public at large - Possibility of destruction - water purification: The substance is normally disposed of to drains. However, no
adverse effects on sewage systems would be anticipated. In
addition the disposal of the substance is expected to be
intermittant and extremely diffuse.

Public at large - Possibility of destruction - others: Not applicable.