Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
from 2004-10-01 to 2004-11-19
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
1992
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
209 °C
Atm. press.:
ca. 1 013 hPa

Test results:


 




























Program



Flash point in oC



Mean in oC



Notes



SEL



221



 



range finding, not used for calculation



ENL



206



209



 



ENL



212


Conclusions:
The flash point is given as the mean value of the duplicate determination. The flash point is therefore 209 ± 3.0 °C.
Executive summary:

A study was conducted to determine the flash point of SIKA Hardener LH according to Regulation (EC) No 440/2008 method A.9, using the Pensky-Martens apparatus (based on closed cup). A flash point of 209.0 ± 3.0 °C was measured, this value being the mean of two independent determinations. An exact determination was not possible because of the reactivity of the test item when getting in contact with ambient oxygen.

Description of key information

The flash point was determined to be 209 ± 3.0 °C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
209 °C

Additional information

A study was conducted to determine the flash point of the test item according to Regulation (EC) No 440/2008 method A.9, using the Pensky-Martens apparatus (based on closed cup). A flash point of 209.0 ± 3.0 °C was measured, this value being the mean of two independent determinations. An exact determination was not possible because of the reactivity of the test item when getting in contact with ambient oxygen.