First-aid measures

Emergency measure - Inhalation: Move person to fresh air; if effects occur, consult a
physician.
Emergency measure - Eyes: Flush eyes thoroughly with water for several minutes. Remove
contact lenses after the initial 1-2 minutes and continue
flushing for several additional minutes. If effects occur,
consult a physician, preferably an ophthalmologist.
Emergency measure - Skin: Wash skin with plenty of water.
Emergency measure - Ingestion: If swallowed, seek medical attention. Do not induce vomiting
unless directed to do so by medical personnel.

Fire-fighting measures

Recommended extinguishing agent: Water fog or fine spray. Dry chemical fire extinguishers.
Carbon dioxide fire extinguishers. Foam. Do not use direct
water stream. May spread fire. Alcohol resistant foams (ATC
type) are preferred. General purpose synthetic foams
(including AFFF) or protein foams may function, but will be
less effective.

Product arising from burning: During a fire, smoke may contain the original material in
addition to combustion products of varying composition which
may be toxic and/or irritating. Combustion products may
include and are not limited to: Carbon monoxide. Carbon
dioxide.

Product determined by test: N

Protective equipment: Wear positive-pressure self-contained breathing apparatus
(SCBA) and protective fire fighting clothing (includes fire
fighting helmet, coat, trousers, boots, and gloves). If
protective equipment is not available or not used, fight
fire from a protected location or safe distance.

Accidental release measures

Emergency measures in case of spillage: Contain spilled material if possible. Absorb with materials
such as: Dirt. Sand. Sawdust. Collect in suitable and
properly labeled containers.

Wash the spill site with water.


Personal Precautions: Isolate area. Keep unnecessary and
unprotected personnel from entering the area. Spilled
material may cause a slipping hazard. Use appropriate safety
equipment.


Environmental Precautions: Prevent from entering into soil,
ditches, sewers, waterways and/or groundwater.

Handling and storage

Handling: General Handling: Avoid contact with eyes. Wash thoroughly
after handling.

Other Precautions: Spills of these organic materials on hot
fibrous insulations may lead to lowering of

the autoignition temperatures possibly resulting in
spontaneous combustion.

Storage: Store in the following material(s): Carbon steel. Stainless
steel. Polypropylene. Polyethylene-lined container. Teflon.
Glass-lined container. Aluminum. Plasite 3066 lined
container. Plasite 3070 lined container. 316 stainless
steel.

Shelf life:

Use within 24 Months

Storage temperature: 20 - 60 °C

Packaging of the substance and or preparation: 216.5 liter capacity steel drums, suitable for packing
miscellaneous liquid chemicals.


bulk shipments

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (IMDG)

Remarksopen allclose all

Air transport ICAO/IATA

Remarks
Transport: not classified for any mode of transportation
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: During fire:

Container may rupture from gas generation in a fire
situation.

Violent steam generation or eruption may occur upon
application of direct water stream to hot liquids

Chemical reaction with water: none

Dust explosion: not applicable - liquid

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: not applicable

Industry - Possibility of neutralisation: not applicable

Industry - Possibility of destruction: controlled discharge: not applicable

Industry - Possibility of destruction - incineration: recommended - energy recovery

Industry - Possibility of destruction - water purification: not applicable

Industry - Possibility of destruction - other: none

Public at large - Possibility of recovery/recycling: not applicable

Public at large - Possibility of neutralisation: not applicable

Public at large - Possibility of destruction: controlled discharge: not applicable

Public at large - Possibility of destruction - incineration: not applicable

Public at large - Possibility of destruction - water purification: not applicable

Public at large - Possibility of destruction - others: not applicable