Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
surface tension
Type of information:
experimental study
Adequacy of study:
key study
Study period:
12 July 2011 - 05 August 2011
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Guideline study conducted in accord with an OECD method and GLP guidelines. The procedure was reported and the results and conclusions were reasonable.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011
Report date:
2012

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.5 (Surface Tension)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 115 (Surface Tension of Aqueous Solutions)
Deviations:
no
GLP compliance:
yes

Test material

Constituent 1
Reference substance name:
MTDID 3285
IUPAC Name:
MTDID 3285
Details on test material:
- Name of test material (as cited in study report): MTDID 3285
- Physical state: solid
- Analytical purity: 86.67%
- Stability under test conditions: stable
- Storage condition of test material: at room temperature in the dark

Results and discussion

Surface tension
Surface tension:
53.3 mN/m
Temp.:
20 °C

Any other information on results incl. tables

Surface tension was determined using a solution that was 90% of the saturation solubility in water. Surface tension of MTDID 3285: see table 1 in attachment.

MTDID 3285 is considered to be surface active.

Applicant's summary and conclusion

Conclusions:
The corrected surface tension of a test solution at 90% of MTDID 3285 saturation solubility in water at 20.0°C is 53.3 mN/m.
Executive summary:

The surface tension test of an aqueous solution of MTDID 3285 was determined using OECD TG 115 harmonized ring method and EEC Directive 92/69 EEC, A.5. A saturated solution was made by preparing a nominal concentration of 1 g/L of the test substance with double distilled water. The solution was ultrasonicated for 10 minutes and stirred at 19.9 ± 0.6°C for 97 hours. After the stirring period, the nominal 1 g/L test solution was centrifuged for 5 minutes at 7549 g. By removing 45 mL of the aqueous phase and mixing with 5 mL double distilled water, the solution was diluted to 90% of saturation and transferred to measurement vessel. Eight measurements were made at 18-25 minutes to show equilibration. The arithmatic mean of the equilibrated values was calibrated against a water standard and corrected using Harkins-Jordan values. The surface tension of a solution of test substance at 90% of saturation at 20.0 °C is 53.3 mN/m. The test substance is considered a surface active material. This study was conducted in accordance with OECD TG 115 and is compliant with GLP standards. Therefore this study is classified as reliable without restrictions.