Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

Emergency measure - Inhalation: Remove from exposure and allow to rest in fresh air. Seek

immediate medical attention.

Emergency measure - Eyes: Irrigate with clean water or isotonic saline for 15 minutes.

Seek immediate medical attention.

Emergency measure - Skin: Remove contaminated clothing, wash skin with soap and water.

If irritation occurs, seek immediate medical attention.

Emergency measure - Ingestion: Rinse mouth with water, give milk or water to drink. Seek

immediate medical attention.

Fire-fighting measures

Recommended extinguishing agent: Dry powder, foam , carbon dioxide or water spray may be

used.

Product arising from burning: Products of combustion may contain oxides of carbon and

nitrogen. Residue from combustion may promote re-ignition of

combustible material.

Product determined by test: N

Protective equipment: Full protective clothing and self-contained breathing

apparatus must be worn.

Fight the fire from a safe distance or protected location.

Accidental release measures

Emergency measures in case of spillage: Evacuate personnel from immediate vicinity.

Wear full personal protective equipment including chemical

resistant gloves, goggles and face mask.

Absorb spillages of solutions with a suitable inert material

(eg. sand or soil). Carefully transfer the spillage to waste

containers, or use a sealed industrial vacuum machine.

Containers filled with waste material must be labelled in

the same way as the original substance containers.

Clean the spillage area with water and detergent. Collect

waste for recovery at a licensed recycling plant. Do not

wash spillages to drains.

Dispose of waste material in accordance with local

regulations by incineraton, or send to a metal recovery

plant.

Handling and storage

Handling: The substance should be stored, handled and used under

conditions of good industrial hygiene and in conformity with

any local regulations in order to avoid exposure by skin,

eye and inhalation exposure.

Engineering controls are necessary to reduce exposure to the

substance.

When exposure cannot be prevented or adequately controlled

appropriate personal protective equipment should be worn.

Such protective equipment should conform to the appropriate

international or national standards as follows;

Chemical protective gloves to Standard prEN374

Chemical protective clothing to Standard EN368

Eye protection to Standard prEN166.

Furthermore, when respiratory protective equipment has to be

used, it must be capable of adequately controlling exposure,

be suitable for the purpose, and conform to the appropriate

international or national standards, such as a dust mask

conforming to EN149 FFP1.

These measures should be regarded as a minimum.

Storage: Store in tightly sealed containers in a cool dark place,

away from sources of ignition.

Packaging of the substance and or preparation: UN specification plastic "Mauser" type containers.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport code: None
Transport: Avoid crushing the containers. In the event of a spillage,
observe the warning labels on the container.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None reported.

Chemical reaction with water: None reported.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: Discharge to the environment will be minimal. Recovery from

spillages or accidental discharge is preferable and should

be sent to recycling plant for recovery of the precious

metal.

Industry - Possibility of neutralisation: No chemical treatment is practicable to neutralise the

hazardous health properties.

No chemical treatment is practicable to neutralise the

hazardous environmental properties.

Industry - Possibility of destruction: controlled discharge: Contaminated containers or spillages of solutions mixed with

inert material (eg. sand or soil) may be disposed of by

landfill at an authorised tip in accordance with local

regulations.

Industry - Possibility of destruction - incineration: The substance can be disposed of by incineration by burning

under controlled conditions at a licensed waste treatment

processor in accordance with local regulations. Stack gases

should be scrubbed, because noxious fumes (eg. carbon and

nitrogen oxides) could be formed.

Industry - Possibility of destruction - water purification: The substance should not normally be discharged directly to

the sewage system or the aqueous environment. However,

adverse effects  on sewage treatment systems would be

unlikely.

Public at large - Possibility of recovery/recycling: The substance will not enter the public domain.

Public at large - Possibility of neutralisation: Not applicable.

Public at large - Possibility of destruction: controlled discharge: Not applicable.

Public at large - Possibility of destruction - incineration: Not applicable.

Public at large - Possibility of destruction - water purification: Not applicable.

Public at large - Possibility of destruction - others: Not applicable.