First-aid measures

Emergency measure - Inhalation: Remover the subject from environment and let him blow his

nose.

Emergency measure - Eyes: Flush eyes with running water for several minutes, while

keeping the eyelids open.

Consult with an ophthalmologist in the case of persistent

pain.

Emergency measure - Skin: Wash affected skin with soap and water.

Emergency measure - Ingestion: If the subject is completely conscious:

-Rinse mouth and administer fresh water.

If the subject is unconscious:

-Not applicable.

Fire-fighting measures

Recommended extinguishing agent: Water, foam, CO2, dry chemical

Product arising from burning: NOx, COx.

Product determined by test: N

Protective equipment: Wear self-contained breathing equipment.

Accidental release measures

Emergency measures in case of spillage: Wear suitable protective clothing during cleaning.

Collect the product with suitable means avoiding dust

formation. Place material into a closed and labelled

container. Dispose in compliance with local/federal and

national regulations.

Send product to an authorised industrial waste incinerator.

Handling and storage

Handling: Keep away from heat sources. Use grounded equipment. No

flames or sparks, no smoking.

In case of dust clouds/fog/fumes, dust masks type P1.

Storage: Keep in original packaging, closed.

Packaging of the substance and or preparation: ± 60L Fibre drums with the product in a double plastic bag

are used.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport: Not classified.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None known.

Chemical reaction with water: None known.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: Not applicable.

Industry - Possibility of neutralisation: Not possible.

Industry - Possibility of destruction: controlled discharge: Not applicable.

Industry - Possibility of destruction - incineration: A660, incinerate not specified.

Industry - Possibility of destruction - water purification: Not recommended. Incineration is preferred.

Industry - Possibility of destruction - other: None.

Public at large - Possibility of recovery/recycling: Not applicable.

Public at large - Possibility of neutralisation: Not applicable.

Public at large - Possibility of destruction: controlled discharge: Not applicable.

Public at large - Possibility of destruction - incineration: Not applicable.

Public at large - Possibility of destruction - water purification: Not applicable.

Public at large - Possibility of destruction - others: Not applicable.