Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2012
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: guideline study according to GLP principles

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report date:
2012

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup

Test material

Results and discussion

Flash point
Flash point:
ca. 162 °C
Atm. press.:
ca. 1 013 hPa
Remarks on result:
other: Pensky-Martens closed cup

Any other information on results incl. tables

Pensky-Martens apparatus

Preliminary test: from room temperature to the preliminary flash point of max. 350 °C. Heating rate. 5.8 °C/min.

Main test performed three times at 1014 -1017 hPa. Heating rate. 5.8 °C/min.

The mean value was rounded to +- 0.5 °C.

Result (mean value of three tests): 162 °C.

Applicant's summary and conclusion

Conclusions:
The result (mean value) of flash point shows 162.0 °C at 1013 hPa