Registration Dossier

Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP - Guideline study.

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2013

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
GLP compliance:
yes

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Density
Type:
relative density
Density:
1.15 other: corresponds to D4
Temp.:
25 °C

Applicant's summary and conclusion