Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: authoritative secondary source

Data source

Reference
Reference Type:
secondary source
Title:
Malonic Acid and Derivatives
Author:
Harald Strittmatter, Stefan Hildbrand, Peter Pollak, Lonza Ltd
Year:
2007
Bibliographic source:
cited in Ullmann's Encyclopedia of Industrial Chemistry and Chemical Technology (online library)
Report Date:
2011

Materials and methods

Test guideline
Guideline:
other: Pensky–Martens, closed cup DIN 51 758.
Principles of method if other than guideline:
Method DIN 51 758.
GLP compliance:
not specified
Type of method:
closed cup

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Flash point
Flash point:
88 °C
Atm. press.:
1 013 hPa

Applicant's summary and conclusion