Registration Dossier

Administrative data

Endpoint:
density
Remarks:
density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2010
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: The study performed based on EEC Directive

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guideline
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Version / remarks:
- EEC Directive 92/69, A.3
GLP compliance:
no
Type of method:
pycnometer method
Remarks:
Ciba method X010 (helium pycnometer)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
- Substance type: organic
- Physical state: solid
- Lot/batch No.: Schweizerhalle HP 10-003

Results and discussion

Density
Type:
density
Density:
1 510.4 kg/m³
Temp.:
20 °C
Remarks on result:
other: room temperature (19-22°C)

Any other information on results incl. tables

The result represents the average of six measurements. Guaranteed reproducibility using a clean, dry and thermally balanced specimen is ± 0.02%.

Applicant's summary and conclusion

Conclusions:
The density of test substance was determined to be 1510.4 kg/m³ at 20°C