Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2010-04-13 to 2011-05-11
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Experimental study which follows standard guidelines

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011
Report Date:
2011

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
GLP compliance:
yes
Type of method:
other: Knudsen cell effusion method coupled to a micro-balance.

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
- Name of test material (as cited in study report):2237JG
- Physical state: Beige and off-white solid
- Lot/batch No.: 2237JG

Results and discussion

Vapour pressure
Temp.:
20 °C
Vapour pressure:
0 Pa

Applicant's summary and conclusion

Conclusions:
The vapour pressure of the test item extrapolated at 20 °C is P = 9.9 x 10-5 Pa.
Executive summary: