Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
oxidising solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Information from migrated NONS file, as per inquiry, permission to refer granted by ECHA

Data source

Reference
Reference Type:
other: Body responsible for the test
Title:
Unnamed
Year:
1996

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.17 (Oxidising Properties (Solids))
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
(R)-α-phenylethylammonium (-)-(1R, 2S)-(1,2-epoxypropyl)phosphonate monohydrate
EC Number:
418-570-8
EC Name:
(R)-α-phenylethylammonium (-)-(1R, 2S)-(1,2-epoxypropyl)phosphonate monohydrate
Cas Number:
25383-07-7
Molecular formula:
C11H18NO4P
IUPAC Name:
(R)-α-phenylethylammonium (-)-(1R, 2S)-(1,2-epoxypropyl)phosphonate monohydrate

Results and discussion

Test results (Oxidising solids)open allclose all
Sample tested:
test mixture (not specified)
Remarks:
migrated information
Parameter:
maximum burning rate
Result:
0.93 other: mm/s (migrated information)
Sample tested:
reference mixture (not specified)
Remarks:
migrated information
Parameter:
maximum burning rate
Result:
1.22 other: mm/s (migrated information)

Applicant's summary and conclusion

Interpretation of results:
other: no oxidising properties
Remarks:
Migrated information
Conclusions:
The maximum burning rate of the TS/CS mixtures (0.93 mm/sec) is lower than the maximum burning rate of RS/CS mixtures (1.22 mm/sec), therefore the test substance can be considered not to have oxidizing properties.