Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 915-671-3 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates â in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Partition coefficient
Administrative data
Link to relevant study record(s)
- Endpoint:
- partition coefficient
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 2008-06-10 to 2008-12-02
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
- Version / remarks:
- 2004
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.8 (Partition Coefficient)
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Remarks:
- Food and Consumer Product Safety Authority (VWA), Den Haag, The Netherlands
- Type of method:
- HPLC method
- Partition coefficient type:
- octanol-water
- Analytical method:
- high-performance liquid chromatography
- Key result
- Type:
- log Pow
- Partition coefficient:
- 2.38
- Remarks on result:
- other: partition coefficient determined at ambient temperature and neutral pH
- Conclusions:
- The Pow and log Pow values of the major component of the test item at neutral pH were measured to be 240 and 2.38, respectively (OECD Guideline 117, HPLC method).
- Endpoint:
- partition coefficient
- Remarks:
- log Pow and LogD
- Type of information:
- (Q)SAR
- Adequacy of study:
- supporting study
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- results derived from a valid (Q)SAR model and falling into its applicability domain, with adequate and reliable documentation / justification
- Justification for type of information:
- Software used: ACD / Percepta von ACD /Labs 2012 Release (Build 2076, 25. July 2012)
SMILES used as inoput:
O=C(C=C1)N(CC(C)CC(C)(C)CCN2C(=O)(C=CC2(=O)))C1(=O)
O=C(C=C1)N(CC(C)(C)CC(C)CCN2C(=O)(C=CC2(=O)))C1(=O) - Qualifier:
- equivalent or similar to guideline
- Guideline:
- other: QSAR method used
- Deviations:
- no
- Principles of method if other than guideline:
- QSAR software used ACD/Percepta from ACD/Labs 2012 Release (Build 2076, 25. July 2012)
- GLP compliance:
- no
- Type of method:
- other: QSAR
- Partition coefficient type:
- octanol-water
- Key result
- Type:
- log Pow
- Partition coefficient:
- 2.72
- Temp.:
- 25 °C
- Remarks on result:
- other: the same value was calculated for both constituents
- Remarks:
- QSAR software used, no pH measured
- Key result
- Type:
- log Pow
- Partition coefficient:
- 1.74
- Temp.:
- 25 °C
- pH:
- >= 0 - <= 14
- Remarks on result:
- other: logD
- Remarks:
- the same values were calculated for both constituents at all pH
- Conclusions:
- A log Pow of 2.72 was calculated for both constituents of the substance (ACD/Percepta from ACD/Labs 2012 Release (Build 2076, 25. July 2012))
Furthermore, a LogD of 1.74 was calculated for both constituents at all pH values by the same software. - Endpoint:
- partition coefficient
- Type of information:
- (Q)SAR
- Adequacy of study:
- supporting study
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- results derived from a valid (Q)SAR model and falling into its applicability domain, with adequate and reliable documentation / justification
- Justification for type of information:
- Software used: EPIWIN 4.1 / KOWWIN v1.68
SMILES used as inoput:
O=C(C=C1)N(CC(C)CC(C)(C)CCN2C(=O)(C=CC2(=O)))C1(=O)
O=C(C=C1)N(CC(C)(C)CC(C)CCN2C(=O)(C=CC2(=O)))C1(=O) - Qualifier:
- equivalent or similar to guideline
- Guideline:
- other: QSAR method used
- Deviations:
- no
- Principles of method if other than guideline:
- Estimation of the Partition Coefficient (n-Octanol/Water) with EPIWIN 4.1 software program KOWWIN Program (v1.68)
- GLP compliance:
- no
- Type of method:
- other: QSAR
- Partition coefficient type:
- octanol-water
- Key result
- Type:
- log Pow
- Partition coefficient:
- 3.09
- Remarks on result:
- other: the same value was calculated for both constituents
- Remarks:
- QSAR result, no information on temperature and pH available.
- Conclusions:
- A log Kow of 3.09 was calculated for both constituents of the substance (EPIWIN v4.1 / KOWWIN v1.68)
Referenceopen allclose all
The equation of the regression line, calibrated using the six selected reference substances, was:
log kâ = 0.415 x log Pow - 0.908 (r = 0.990, n = 12).
Other than the major component, two impurities with peak area > 1% have been identified. The Pow, log Pow and % area are reported in the following table.
|
Pow |
log Pow |
Area % |
Major component |
240 |
2.38 |
75 |
Impurity |
73 |
1.86 |
23 |
Impurity |
32 |
1.51 |
1.4 |
Constituent 01
Calculated LogP: 2.72 +- 0.36
LogD at pH 1.7 (Stomach): 1.74
LogD at pH 4.6 (Duodenum): 1.74
LogD at pH 6.5 (Jejunum and Ileum): 1.74
LogD at pH 7.4 (Blood): 1.74
LogD at pH 8.0 (Colon): 1.74
Constituent 02
Calculated LogP: 2.72 +- 0.36
LogD at pH 1.7 (Stomach): 1.74
LogD at pH 4.6 (Duodenum): 1.74
LogD at pH 6.5 (Jejunum and Ileum): 1.74
LogD at pH 7.4 (Blood): 1.74
LogD at pH 8.0 (Colon): 1.74
Constituent 01
KOWWIN Program (v1.68) Results:
===============================
Log Kow(version 1.68 estimate): 3.09
SMILES : O=C(C=C1)N(CC(C)CC(C)(C)CCN2C(=O)(C=CC2(=O)))C1(=O)
CHEM :
MOL FOR: C17 H22 N2 O4
MOL WT : 318.38
-------+-----+--------------------------------------------+---------+--------
TYPE | NUM | LOGKOW FRAGMENT DESCRIPTION | COEFF | VALUE
-------+-----+--------------------------------------------+---------+--------
Frag | 3 | -CH3 [aliphatic carbon] | 0.5473 | 1.6419
Frag | 4 | -CH2- [aliphatic carbon] | 0.4911 | 1.9644
Frag | 1 | -CH [aliphatic carbon] | 0.3614 | 0.3614
Frag | 4 | =CH- or =C< [olefinc carbon] | 0.3836 | 1.5344
Frag | 2 | -N< [aliphatic attach] |-1.8323 | -3.6646
Frag | 4 | -C(=O)N [aliphatic attach] |-0.5236 | -2.0944
Frag | 1 | -tert Carbon [3 or more carbon attach] | 0.2676 | 0.2676
Factor| 2 | Pyrrole-2,5-dione ring correction | 1.4227 | 2.8454
Const | | Equation Constant | | 0.2290
-------+-----+--------------------------------------------+---------+--------
Log Kow = 3.0851
Constituent 02
KOWWIN Program (v1.68) Results:
===============================
Log Kow(version 1.68 estimate): 3.09
SMILES : O=C(C=C1)N(CC(C)(C)CC(C)CCN2C(=O)(C=CC2(=O)))C1(=O)
CHEM :
MOL FOR: C17 H22 N2 O4
MOL WT : 318.38
-------+-----+--------------------------------------------+---------+--------
TYPE | NUM | LOGKOW FRAGMENT DESCRIPTION | COEFF | VALUE
-------+-----+--------------------------------------------+---------+--------
Frag | 3 | -CH3 [aliphatic carbon] | 0.5473 | 1.6419
Frag | 4 | -CH2- [aliphatic carbon] | 0.4911 | 1.9644
Frag | 1 | -CH [aliphatic carbon] | 0.3614 | 0.3614
Frag | 4 | =CH- or =C< [olefinc carbon] | 0.3836 | 1.5344
Frag | 2 | -N< [aliphatic attach] |-1.8323 | -3.6646
Frag | 4 | -C(=O)N [aliphatic attach] |-0.5236 | -2.0944
Frag | 1 | -tert Carbon [3 or more carbon attach] | 0.2676 | 0.2676
Factor| 2 | Pyrrole-2,5-dione ring correction | 1.4227 | 2.8454
Const | | Equation Constant | | 0.2290
-------+-----+--------------------------------------------+---------+--------
Log Kow = 3.0851
Description of key information
Log Pow = 2.38 at ambient temperature, pH ca. 7 (OECD Guideline 117, HPLC method)
Key value for chemical safety assessment
- Log Kow (Log Pow):
- 2.38
- at the temperature of:
- 25 °C
Additional information
The Pow and log Pow values of the major component of the test item: at neutral pH the Pow is 2.4E2 and the log Pow is 2.38. The QSAR estimation with ACD Labs software shows a log Pow at 2.72 for both conmponents. The QSAR estimation with EPIWIN 4.1 (KOWWIN Program (v1.68)) shows a Log Kow of 3.09 for both components.
Furthermore, the LogD of 1.74 shows no pH dependencies. The results are equal for both components.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.