Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
10 September 2007
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study conducted in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies, which do not affect the quality of relevant results.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008
Report date:
2008

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
(Date of inspection: 21/08/2007 Date of signature: 15/10/2007)
Type of distribution:
counted distribution

Test material

Constituent 1
Chemical structure
Reference substance name:
-
EC Number:
417-560-0
EC Name:
-
Cas Number:
67881-98-5
Molecular formula:
C11H22NO6P
IUPAC Name:
trimethyl[2-({2-[(2-methylprop-2-enoyl)oxy]ethyl phosphonato}oxy)ethyl]azanium
Details on test material:
- Name of test material (as cited in study report): MPC
- Substance type: White powder
- Physical state: Solid
- Lot/batch No.:270103
- Storage condition of test material: at approximately 4°C, in the dark until 26th October and then over silica gel at approximately 4 °C in the dark.

Results and discussion

Particle size
Percentile:
D50
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
Particle size distribution at different passages
No.:
#1
Size:
< 100 µm
Distribution:
< 0.662 %

Applicant's summary and conclusion

Conclusions:
The proportion of test material having an inhalable particle size of less than 100 µm was 0.662%. The test material has beend determined to be essentially non-inhalable.
Executive summary:

The test material has been determined to be essentially non-inhalable using OECD Test Guideline 110 (inhalable particle size of less than 100 µm was < 0.662%).