Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
hydrolysis
Type of information:
experimental study
Adequacy of study:
key study
Study period:
11 February 2011 – 04May 2011
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: This study has been performed according to OECD and EC guidelines and in compliance with GLP principles.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011
Report date:
2011

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 111 (Hydrolysis as a Function of pH)
Version / remarks:
(2004)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method C.7 (Degradation: Abiotic Degradation: Hydrolysis as a Function of pH)
Version / remarks:
(Official Journal of the European Union no. L142, May 31, 2008)
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
- Name of test material (as cited in study report): E-BW102
- Description: Reddish brown powder
- Batch: MB-1
- Test substance storage: At room temperature protected from light
- Stability under storage conditions: Stable
- Expiry date: 23 December 2015
Radiolabelling:
no

Study design

Analytical monitoring:
yes
Details on sampling:
The concentration of the test substance in the test samples was determined immediately after preparation (t=0) and after 5 days. The samples taken at t=5 days were cooled to room temperature using running tap water. The samples were diluted by a factor of 100 with water to
obtain concentrations into the calibration range and analysed.

Blank buffer solutions were treated similarly as the test samples and analysed at t=0.

The pH of each of the test solutions (except for the blanks) was determined at each sampling time.
Buffers:
- pH: 4
- Type and final molarity of buffer: Acetate buffer, 0.1 M
- Composition of buffer: solution of 16.6% 0.1 M sodium acetate and 83.4% 0.1 M acetic acid. The buffer contains 0.0009% (w/v) sodium azide.

- pH: 7
- Type and final molarity of buffer: Phosphate buffer, 0.1 M
- Composition of buffer: solution of 0.1 M potassium dihydrogenphosphate adjusted to pH 7 using 10 N sodium hydroxide. The buffer contains
0.0009% (w/v) sodium azide.

- pH: 9
- Type and final molarity of buffer: Borate buffer, 0.1 M
- Composition of buffer: solution of 0.1 M boric acid and 0.1 M potassium chloride adjusted to pH 9 using 10 N sodium hydroxide. The buffer
contains 0.0009% (w/v) sodium azide.
Details on test conditions:
All solutions containing the test substance were protected from light.

Test substance solutions were prepared in the buffer solutions at a target concentration of 100 mg/l. Each solution was filter-sterilised through a 0.2 μm FP 30/0.2 CA-S filter (Whatman, Dassel, Germany) and transferred into a sterile vessel. To exclude oxygen, nitrogen gas was purged through the solution for 5 minutes. For each sampling time, duplicate sterile vessels under vacuum were filled with 6 ml test solution and placed in the dark in a temperature controlled environment at 50.0°C +/- 0.2°C.
Duration of testopen allclose all
Duration:
5 d
pH:
4
Initial conc. measured:
130 - 133 mg/L
Duration:
5 d
pH:
7
Initial conc. measured:
147 mg/L
Duration:
5 d
pH:
9
Initial conc. measured:
123 - 124 mg/L
Number of replicates:
2 measurements at each pH (separate vessels)

Results and discussion

Preliminary study:
At pH 4, pH 7 and pH 9 a degree of hydrolysis of < 10% was observed after 5 days. It demonstrated that the half-life time of the test substance at 25°C is > 1 year. According to the guideline, no further tests were required.

No test substance was detected in the blank buffer solutions.
Test performance:
The mean recoveries in buffer solutions at pH 4 and pH 9 fell within the acceptable range for nonlabelled chemicals of 70-110%. It demonstrated that the analytical method was adequate to support the hydrolysis study on the test substance.
The mean recovery in buffer solution pH 7 was slightly higher than the criterion 70-110% (112%). This was still considered acceptable.
Total recovery of test substance (in %)open allclose all
% Recovery:
106 - 108
pH:
4
Temp.:
50 °C
% Recovery:
112 - 113
pH:
7
Temp.:
50 °C
% Recovery:
104 - 105
pH:
9
Temp.:
50 °C

Any other information on results incl. tables

Preliminary test – hydrolysis of the test substance at pH 4, pH 7 and pH 9

pH code

Sampling time

Analysed concentration
[mg/l]

Degree of hydrolysis
[%]

Actual pH

Individual

Mean

 

 

 

 

 

 

pH 4

0 hours

130

 

 

4.0

 

 

133

 

 

4.0

 

5 days

133

- 1.1

- 3.9

4.0

 

 

140

- 6.6

 

4.0

 

 

 

 

 

 

pH 7

0 hours

147

 

 

7.1

 

 

147

 

 

7.1

 

5 days

143

2.7

2.0

7.1

 

 

145

1.3

 

7.1

 

 

 

 

 

 

pH 9

0 hours

123

 

 

9.0

 

 

124

 

 

9.0

 

5 days

133

- 8.0

- 6.3

9.0

 

 

129

- 4.6

 

9.0

 

 

 

 

 

 

Applicant's summary and conclusion

Conclusions:
The preliminary test (Tier 1) was performed for the determination of the rate of hydrolysis of E-BW102 at pH values normally found in the environment (pH 4-9).

At each pH value a degree of hydrolysis of < 10% was observed after 5 days. According to the guideline, performance of the main study (Tier 2) was not required.

From the results it was concluded that the half-life times of E-BW102 at 25°C are > 1 year at pH4, pH7 and pH9.