Administrative data

First-aid measures

General advice:

Take off all contaminated clothing immediately.

If inhaled:

Take the person into the fresh air and keep him warm, let him rest; if there is difficulty in breathing, medical advice is required.

In case of skin contact:

In case of skin contact wash affected areas thoroughly with soap and plenty of water.

Consult a doctor in the event of a skin reaction.

In case of eye contact:

Hold the eyes open and rinse with preferably lukewarm water for a sufficiently long period of time (at least 10 minutes).

Contact an ophthalmologist.

If swallowed:

If swallowed, rinse mouth with water (only if the person is conscious). DO NOT induce the patient to vomit, medical advice is required.

Fire-fighting measures

Suitable extinguishing media:

Carbon dioxide (CO2), Foam, extinguishing powder, in cases of larger fires, water spray should be used.

Unsuitable extinguishing media:

High volume water jet.

Special hazards arising from the substance or mixture:

Burning releases carbon monoxide, carbon dioxide, oxides of nitrogen and traces of hydrogen cyanide.

In the event of fire and/or explosion do not breathe fumes.

Cool endangered vessels and containers with sprayed water.

Heating raises pressure with consequent risk of bursting and explosion.

Advice for fire-fighters:

During fire-fighting respirator with independent air-supply and airtight garment is required.

Do not allow contaminated extinguishing water to enter the soil, ground-water or surface waters.

Accidental release measures

Personal precautions, protective equipment and emergency procedures:

Put on protective equipment.

Respiratory protection:

Put on full-mask respirator with filter type ABEK.

Hand protection:

Conditionally suitable materials for protective gloves; EN 374-3:

Nitrile rubber - NBR (>= 0.35 mm). Breakthrough time not tested; dispose of immediately after contamination.

Eye protection:

Wear eye/face protection.

Skin and body protection:

Wear suitable protective clothing.

Keep away from sources of ignition.

Ensure adequate ventilation/exhaust extraction.

Keep unauthorized persons away.

Environment related measures:

Do not allow to escape into waterways, wastewater or soil.

Methods and material for containment and cleaning up: Contain liquid and pump it away.

Take up with absorbent for chemicals or, if necessary with dry sand and store in closed containers.

Disposal considerations:

Dispose in accordance with applicable international, national and local laws, ordinances and statutes.

For disposal within the EC, the appropriate code according to the European Waste Catalogue (EWC) should be used.

Handling and storage

Precautions for safe handling:

Handle in accordance with good industrial hygiene and safety practice. Avoid contact with skin and eyes.

In all workplaces or parts of the plant where high concentrations of aerosols and/or vapors may be generated (e.g. during pressure release, mold venting or when cleaning mixing heads with an air blast), appropriately located exhaust ventilation must be provided in such a way that the WEL

is not exceeded. The air should be drawn away from the personnel handling the product The efficiency of the exhaust equipment should be periodically checked.

Precautions should generally be taken against electrostatic charges according to the equipment used and the way the product is handled and

packaged.

Explosion protection required. When setting up and operating electrical equipment, it is essential to observe the "German regulation on Electrical Equipment in Hazardous Locations", (cf. ZH 1/309, which corresponds to ElexV), VDE 0165 and ZH1/10 "Guidelines on avoidance of risks

from explosive mixtures with air. Ventilation systems must be installed to prevent the formation of

explosive vapor/air mixtures.

Keep away from foodstuffs, drinks and tobacco. Wash hands before breaks and at the end of workday. Keep working clothes separately.

Change contaminated or soaked clothing immediately.

Conditions for safe storage, including any incompatibilities:

Keep container tightly closed and dry.

Storage temperature regarding personal safety: max. 50 °C.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
not required
Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Disposal considerations