Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Report Date:
2010

Materials and methods

Test guideline
Qualifier:
equivalent or similar to
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Deviations:
not specified
Principles of method if other than guideline:
The guideline is ASTM D93 - Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester
GLP compliance:
not specified
Type of method:
closed cup

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Flash point
Flash point:
ca. 190.4 °C
Remarks on result:
other: According to ASTM 93

Applicant's summary and conclusion