Registration Dossier

Administrative data

Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2007
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Report Date:
2007

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
other: ASTM 93
Principles of method if other than guideline:
The guideline is ASTM D93 Standard Test Methods for Flash Point by PenskyMartens Closed Cup Tester. Similar guide: ISO 2719:2002 (Determination of f lash point PenskyMartens closed cup method)
GLP compliance:
not specified
Type of method:
closed cup

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Flash point
Flash point:
ca. 69 °C
Remarks on result:
other: No data of pressure

Applicant's summary and conclusion