Registration Dossier

Administrative data

Endpoint:
stability: thermal, sunlight, metals, other
Remarks:
Migrated from section 'Stability: thermal, sunlight, metals'
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
2013
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: well performed stuy according to company SOP

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report Date:
2013

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
other: company SOP
Principles of method if other than guideline:
Determination of the decomposition temperatue with DSC
GLP compliance:
no

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
Purity: 98.8 %

Results and discussion

For thermal stability study

Test substance thermally stable:
no
Operating temperature
Operating temp.:
> 25 - < 450 °C
Remarks on result:
other: The product starts to decompose in the sealed vial at 202°C
Sublimation:
no
Transformation products:
not measured

For study on stability to sunlight

Test substance stable to sunlight:
not determined

For study on stability to metals

Test substance stable to metals / metal ions:
not determined

Applicant's summary and conclusion

Conclusions:
The decomposition temperature of the substance is 202°C.
Executive summary:

The thermal stabikity of the substance was determied by DSC. The product starts to decompose in the sealed vial at 202°C