Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
other information
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: scientifically acceptable study, basic data given

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011
Report date:
2011

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Qualifier:
according to guideline
Guideline:
ISO 13736:1997 (Petroleum products and other liquids - Determination of flash point - Abel closed cup method)
Version / remarks:
1997
GLP compliance:
no
Type of method:
closed cup

Test material

Constituent 1
Chemical structure
Reference substance name:
(2-hydroxyethyl)(3-hydroxypropyl)dimethylammonium chloride
EC Number:
278-860-3
EC Name:
(2-hydroxyethyl)(3-hydroxypropyl)dimethylammonium chloride
Cas Number:
78182-00-0
Molecular formula:
C7H18NO2.Cl
IUPAC Name:
3-hydroxy-N-(2-hydroxyethyl)-N,N-dimethylpropan-1-aminium chloride
Details on test material:
name of test material (as cited in study report): Lutensit® DMAC
Analytical purity: >65%<75% (%w/w) (aqueous solution)


Results and discussion

Any other information on results incl. tables

DIN EN ISO 2719: no flash point detecable, ignition flame goes out at approx. 50°C

DIN EN ISO 13736: no flash point detecable up to 70°C

Applicant's summary and conclusion