Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 939-448-5 | CAS number: 1469983-46-7
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Toxicity to microorganisms
Administrative data
Link to relevant study record(s)
- Endpoint:
- activated sludge respiration inhibition testing
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 2012-04-16 to 2012-04-17
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: Guideline study, GLP, All validity criteria fulfilled, complete identification of test substance
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
- Deviations:
- no
- GLP compliance:
- yes
- Analytical monitoring:
- no
- Vehicle:
- no
- Details on test solutions:
- PREPARATION AND APPLICATION OF TEST SOLUTION (especially for difficult test substances)
- Method: No vehicle, directly weighing, overnight stirring
- Eluate: Synthetic waste water acc. to OECD 209
- Differential loading: 6.50 - 13.0 - 26.0 - 52.0 - 104.0 mg/L
- Controls: Triplicates at the beginning of the test + triplicates at the end of the test - Test organisms (species):
- activated sludge of a predominantly domestic sewage
- Details on inoculum:
- - Preparation of inoculum for exposure: Non adapted activated sludge from the sewage plant at sarstedt (Municipal sewage treatment plant of 31157 Sarstedt, Germany)
- Pretreatment: Washed twice with autoclaved tap water and adjusted to a dry weight concentration of 3 g/L +/- 10 %
- Dry sludge concentration: 3.12 g/L (corresponding to 1.56 g/L suspended solids in the test vessels) - Test type:
- static
- Water media type:
- freshwater
- Limit test:
- no
- Total exposure duration:
- 3 h
- Hardness:
- Not determined
- Test temperature:
- 21 - 22 °C
- pH:
- 7.99 (activated sludge)
7.51 (synthetic waste water) - Salinity:
- None, freshwater
- Details on test conditions:
- TEST SYSTEM
- Test vessel: 500 mL Erlenmeyer flask, DIN 12380
- Aeration: Permanent
- No. of vessels per concentration (replicates): 3
- No. of vessels per control (replicates): 3
- Composition of test medium:
250 mL inoculum
16 mL synthetic waste water
234 mL autoclaved tap water
Test or reference item concentration (directly weighed into each test vessel)
EFFECT PARAMETERS MEASURED (with observation intervals if applicable) :
Determination of respiration rates subsequently to an incubation period of 3 h
TEST CONCENTRATIONS
- Range finding study
Inhibition of Respiration (Preliminary Test)
Nominal Test Item Concentration Pretreatment Inhibition [%]
[mg/L]
10 Stirring overnight 6
100 93
1000 97 - Reference substance (positive control):
- yes
- Remarks:
- Copper (II) sulphate pentahydrate p.a.
- Duration:
- 3 h
- Dose descriptor:
- NOEC
- Effect conc.:
- 6.25 mg/L
- Nominal / measured:
- nominal
- Conc. based on:
- act. ingr.
- Basis for effect:
- inhibition of total respiration
- Remarks:
- respiration rate
- Duration:
- 3 h
- Dose descriptor:
- EC50
- Effect conc.:
- 35.3 mg/L
- Nominal / measured:
- nominal
- Conc. based on:
- act. ingr.
- Basis for effect:
- inhibition of total respiration
- Remarks:
- respiration rate
- Remarks on result:
- other: (31.2-40.0)
- Details on results:
- - Any observations (e.g. precipitation) that might cause a difference between measured and nominal values: None
- Results with reference substance (positive control):
- - Results with reference substance valid? Yes
- Relevant effect levels: EC50: 93.3 (89.3 - 97.3) mg/L - Reported statistics and error estimates:
- The NOEC was determined by calculation of statistical significance of the inhibition of respiration in comparison to the control. One Way Analysis of Variance (ANOVA) and DUNNETT’s test was used for NOEC calculations. When running a One Way Analysis of Variance a Normality test and an Equal Variance test were done first. P-values for both Normality and Equal Variance test are 0.05. The a-value (acceptable probability of incorrectly concluding that there is a difference) is a=0.05.
The EC-values of the test item was calculated by sigmoidal dose-response regression and the EC50-value of the reference item by linear regression using software GraphPad Prism5, GRAPHPAD SOFTWARE, INC. Calculation of the confidence intervals for the EC-values were carried out using standard procedures. - Validity criteria fulfilled:
- yes
- Conclusions:
- The NOEC of the test item 3-(Isodecyloxy)propylamine, acetate is 6.25 mg a.i./L. The test item is not toxic at the concentration of 6.25 mg a.i./L to activated sludge of a municipal sewage treatment plant. The EC50 of the test item is 35.3 mg a.i./L.
- Executive summary:
A Respiration Inhibition Test with activated sludge according to OECD Guideline No. 209 was
carried out with the test item 3-(Isodecyloxy)propylamine, acetate (batch number: 110727JC) from 2012-04-16 to 2012-04-17, with the experimental phase on 2012-04-17 at Dr.U.Noack-Laboratorien, D-31157 Sarstedt. Test system was activated sludge of the municipal treatment plant of D-31137 Hildesheim. The test was carried out under static conditions with the substance concentrations 6.25 – 12.5 – 25.0 – 50.0 – 100 mg/L (a.i.), corresponding to the nominal test item concentrations 6.50 – 13.0 – 26.0 – 52.0 – 104 mg/L. The respiration rates of the control, reference and test item replicates were measured after a contact time of three hours, and the inhibitory effects of the test and reference item were determined in comparison to the control respiration rates. The mean inhibition of respiration for the test item replicates ranged from 9 % to 94 %.
In order to check the activity of the test system and the test conditions a reference test was carried out with copper (II) sulphate pentahydrate as reference item and the reference toxicity was determined. The EC50-value for the reference item was 93.3 mg/L.
EC-Values with Confidence Interval of 3-(Isodecyloxy)propylamine, acetate
EC-values
Confidence interval
[mg a.i./L]
P = 95 [%]
[mg a.i./L]
NOEC*
6.25
–
EC20
20.0
14.3 - 23.9
EC50
35.3
31.2 - 40.0
EC80
55.3
48.2 - 65.0
*) no statistically significant effect (p 0.001) , ANOVA, Dunnett`s Method
The NOEC of the test item 3-(Isodecyloxy)propylamine, acetate is 6.25 mg a.i./L.
The test item is not toxic at the concentration of 6.25 mg a.i./L to activated sludge
of a municipal sewage treatment plant. The EC50 of the test item is 35.3 mg a.i./L.
Reference
Oxygen Uptake Rates, Specific Respiration Rates and Inhibition of the Respiration of the Control and Reference Item Concentrations
Reference Item Concentration |
|
Oxygen Uptake Rate |
Specific Respiration Rate |
|
Mean Inhibition |
Control |
1 |
30.0 |
19.2 |
– |
– |
2 |
31.6 |
20.3 |
|||
3 |
30.4 |
19.5 |
|||
4 |
30.4 |
19.5 |
|||
5 |
30.4 |
19.5 |
|||
6 |
29.2 |
18.7 |
|||
58 |
1 |
20.4 |
33 |
30 |
|
2 |
20.8 |
31 |
|||
3 |
22.0 |
27 |
|||
100 |
1 |
15.2 |
50 |
52 |
|
2 |
14.8 |
51 |
|||
3 |
14.0 |
54 |
|||
180 |
1 |
6.4 |
79 |
79 |
|
2 |
6.4 |
79 |
|||
3 |
6.8 |
78 |
Mean specific respiration rate of the control: 19.4 mg O2/g×h
Coefficient of variation of oxygen uptake rates of the control: 2.6 %
Suspended solids in the test vessel: 1.56 g/L
Oxygen Uptake Rates and Inhibition
of the Respiration
of the Test Item Concentrations
|
|
Oxygen Uptake Rate |
|
Mean Inhibition |
6.25 |
1 |
25.2 |
17 |
9 |
2 |
28.4 |
6 |
||
3 |
27.2 |
10 |
||
4 |
28.0 |
8 |
||
5 |
29.2 |
4 |
||
12.5 |
1 |
26.4 |
13 |
17 |
2 |
28.0 |
8 |
||
3 |
23.2 |
23 |
||
4 |
25.6 |
16 |
||
5 |
22.4 |
26 |
||
25 |
1 |
21.6 |
29 |
27 |
2 |
32.4 |
-7 |
||
3 |
17.6 |
42 |
||
4 |
19.2 |
37 |
||
5 |
19.6 |
35 |
||
50 |
1 |
6.8 |
78 |
75 |
2 |
7.2 |
76 |
||
3 |
8.4 |
72 |
||
4 |
8.0 |
74 |
||
5 |
7.6 |
75 |
||
100 |
1 |
2.8 |
91 |
94 |
2 |
1.6 |
95 |
||
3 |
2.0 |
93 |
||
4 |
1.6 |
95 |
||
5 |
1.6 |
95 |
Description of key information
3-(Isodecyloxy)propylamine, acetate (CAS no 28701 -67 -9) is not toxic at the concentration of 6.25 mg a.i./L to activated sludge of a municipal sewage treatment plant.
The EC50 is 35.3 mg a.i./L.
3-(Isodecyloxy)propylamine (CAS no 30113 -45 -2) is not toxic (EC10) at the concentration of 13 mg a.i./L to activated sludge of a municipal sewage treatment plant.
The EC50 is 23.6 mg a.i./L.
For riks assessment the lowest NOEC value of 6.25 mg a.i./L will be used as a worst-case.
Key value for chemical safety assessment
- EC50 for microorganisms:
- 35.3 mg/L
- EC10 or NOEC for microorganisms:
- 6.25 mg/L
Additional information
A Respiration Inhibition Test with activated sludge according to OECD Guideline No. 209 was performed with 3-(Isodecyloxy)propylamine, acetate and also with 3-(Isodecyloxy)propylamine
The lowest NOEC/EC10 is found for 3-(Isodecyloxy)propylamine, acetate of 6.25 mg a.i./L.
The substance is not toxic at the concentration of 6.25 mg a.i./L to activated sludge of a municipal sewage treatment plant. The EC50 of the test item is 35.3 mg a.i./L.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.
