Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
explosiveness
Type of information:
experimental study
Adequacy of study:
key study
Study period:
1985
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Analogue substance tested.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1985

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
GLP compliance:
yes
Remarks:
study conducted before official GLP-statement necessary, but quality observed study

Test material

Constituent 1
Reference substance name:
Analogue substance (refer to IUCLID chapter 13)
IUPAC Name:
Analogue substance (refer to IUCLID chapter 13)

Results and discussion

Small-scale preliminary testsopen allclose all
Parameter:
other: More sensitive to shock than m-dinitrobenzene
Remarks:
migrated information
Remarks on result:
negative (not further specified)
Parameter:
other: More sensitive to friction than m-dinitrobenzene
Remarks:
migrated information
Remarks on result:
negative (not further specified)
Parameter:
other: Explosive under influence of flame
Remarks:
migrated information
Remarks on result:
negative (not further specified)
Parameter:
other: Explosive (not specified)
Remarks:
migrated information
Remarks on result:
negative (not further specified)

Applicant's summary and conclusion

Interpretation of results:
non explosive
Remarks:
Migrated information
Conclusions:
The test on explosiveness was conducted with the analogue substance. As a result, the analogue substance was found to be not explosive. According to the structural similarity of the analogue substance and the substance subject of registration it can be concluded that the substance subject of registration is not considered to be explosive.