Registration Dossier

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Sep 2020 - March 2021
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
yes
Remarks:
This deviation did not have an adverse impact to the study.
GLP compliance:
yes (incl. QA statement)
Type of method:
gas saturation method
Key result
Test no.:
#1
Temp.:
25 °C
Vapour pressure:
0.032 Pa
Conclusions:
The vapor pressure of FR-513 at 25°C was determined to 3.17E-02  6.71E-03 Pa, which corresponds to a value of 2.38E-04 Torr. There were no known circumstances that may have adversely affected the quality or integrity of the data.
Executive summary:

The vapor pressure of FR-513 at 25°C was determined to 3.17E-02 ± 6.71E-03 Pa, which corresponds to a value of 2.38E-04 Torr. 

There were no known circumstances that may have adversely affected the quality or integrity of the data.

Description of key information

Key value for chemical safety assessment

Vapour pressure:
0.032 Pa
at the temperature of:
25 °C

Additional information