Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 432-130-2 | CAS number: 119345-01-6
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Hydrolysis
Administrative data
- Endpoint:
- hydrolysis
- Study period:
- Not specified
- Data waiving:
- study technically not feasible
- Justification for data waiving:
- other:
Data source
Reference
- Reference Type:
- other: Body responsible for the test
- Title:
- Unnamed
- Year:
- 1 999
- Report date:
- 1999
Materials and methods
Test guideline
- Qualifier:
- according to guideline
- Guideline:
- EU Method C.7 (Degradation: Abiotic Degradation: Hydrolysis as a Function of pH)
- GLP compliance:
- yes
Test material
- Reference substance name:
- -
- EC Number:
- 432-130-2
- EC Name:
- -
- Cas Number:
- 119345-01-6
- Molecular formula:
- Not applicable ( a generic molecular formula cannot be provided for this UVCB substance)
- IUPAC Name:
- Reaction products of phosphorous trichloride, with 1,1′-biphenyl and 2,4-bis(1,1-dimethylethyl)phenol
- Details on test material:
- no data
Constituent 1
- Specific details on test material used for the study:
- Details on properties of test surrogate or analogue material (migrated information):
no data - Radiolabelling:
- not specified
Study design
- Analytical monitoring:
- not specified
- Details on sampling:
- no data
- Buffers:
- no data
- Estimation method (if used):
- no data
- Details on test conditions:
- no data
- Number of replicates:
- no data
- Positive controls:
- not specified
- Negative controls:
- not specified
- Statistical methods:
- no data
Results and discussion
- Preliminary study:
- no data
- Test performance:
- no data
- Transformation products:
- not specified
- Details on hydrolysis and appearance of transformation product(s):
- Comments: Because of the insufficient solubility of the substance a test in the water and in the buffers it could not perform test preliminary hydrolysis. For more information please refer to the test report.
- Other kinetic parameters:
- no data
- Details on results:
- Comments: Because of the insufficient solubility of the substance a test in the water and in the buffers it could not perform test preliminary hydrolysis. For more information please refer to the test report.
Applicant's summary and conclusion
- Validity criteria fulfilled:
- not applicable
- Conclusions:
- In accordance with REACH Annex VIII column 2, the study does not need to be conducted if the substance is readily biodegradable or highly insoluble in water. According to the SNIF file provided by ECHA, an attempt was made to conduct the study in accordance with Directive 92/69/CEE, C.7. Because of the insufficient solubility of the substance, it was not possible to conduct the test in water and the associated buffers to assess preliminary hydrolysis.
- Executive summary:
Information from migrated NONS file, as per inquiry number 06-0000020725-70-0000, permission to refer granted by ECHA.
Study conducted to GLP (taken from SNIF file). Registrant referring to studies >12 years old at the permission of ECHA.
In accordance with REACH Annex VIII column 2, the study does not need to be conducted if the substance is readily biodegradable or highly insoluble in water. According to the SNIF file provided by ECHA, an attempt was made to conduct the study in accordance withDirective92/69/CEE,C.7. Because of the insufficient solubility of the substance, it was not possible to conduct the test in water and the associated buffers to assess preliminary hydrolysis.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.